low voltage

Hotline

KFD2-SOT3-Ex1.LB Pepperl Fuchs safety barrier

description:KFD2-SOT3-Ex1.LB Switch Amplifier...
BASIC INFO


KFD2-SH-Ex1.T.OP

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Transistor, SIL/IEC 61508
 

KFD2-SOT3-Ex1.LB

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
 

KFD2-SOT3-Ex1.LB.IO

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
 

KFD2-SOT3-Ex2

Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
 

KFD2-SOT3-Ex2.IO

Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
 

KFD2-SR2.Ex1.W

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508
 

KFD2-SR2-Ex1.W.LB

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508
 

KFD2-SR2-Ex2.W

Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508
 

KFD2-SR3-Ex2.2S

Switch Amplifier

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508
 

KFD2-SRA-Ex4

Switch Amplifier

4-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 50 % less wiring, 2:1 technology, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay


KFD2-ST3-Ex1.LB

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508

         

KFD2-SH-Ex1.T.OP

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Transistor, SIL/IEC 61508

KFD2-SOT3-Ex1.LB

Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508

 

KFD2-SOT3-Ex1.LB.IO

Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508

 

KFD2-SOT3-Ex2

Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508

 

KFD2-SOT3-Ex2.IO

Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508

 

KFD2-SR2.Ex1.W

Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508

 

KFD2-SR2-Ex1.W.LB

Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508

 

KFD2-SR2-Ex2.W

Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508

 

KFD2-SR3-Ex2.2S

Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: relay, SIL/IEC 61508

 

KFD2-SRA-Ex4

Switch Amplifier

1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Transistor, SIL/IEC 61508

 