low voltage

Hotline

MTL4576-THC - MTL 4500 Intrinsically Safe Isolators

description:MTL4576-THC – MTL5576-THC TEMPERATURE CONVERTER mV/THC input, 2-channel ...
BASIC INFO
Production overviews
       
                                 MTL 4500 Intrinsically Safe Isolators  MTL4576-THC

MTL4576-THC – MTL5576-THC TEMPERATURE CONVERTER mV/THC input, 2-channel The MTLx576–THC converts low–level dc signals from temperature sensors mounted in a hazardous–area into 4/20mA currents for driving safe–-area loads. Software selectable features include linearisation for standard thermocouple types, ranging, monitoring, testing and tagging. Configuration is carried out using a personal computer. The hazardous–area connections include cold–junction compensation and do not need to be ordered separately.

                                       


MTL4576-THC safe barrier product specification
SPECIFICATION
See also common specification
Number of channels
Two
Signal source
THC types J, K, T, E, R, S, B or N to BS 60584 and XK
mV input
Location of signal source
Zone 0, IIC, T4–6 hazardous area
Division 1, Group A, hazardous location
Input signal range
–75 to +75mV
Input signal span
3 to 150mV
Cold junction compensation
Automatic or selectable
Cold junction compensation error
≤ 1.0°C
Common mode rejection
120dB for 240V at 50Hz or 60Hz
Series mode rejection
40dB for 50Hz or 60Hz
Calibration accuracy (at 20°C)
(includes hysteresis, non-linearity and repeatability)
Input: ±15µV or ±0.05% of input value
(whichever is greater)
Output: ±16µA
Temperature drift (typical)
Input: ±0.003% of input value/°C
Output: ±0.6µA/°C
Safety drive on sensor burnout
Upscale, downscale, or off
Output range
4 to 20mA nominal into 300Ω max.
Maximum lead resistance
300Ω with safety drive on sensor failure enabled
>10kΩ with safety drive on sensor failure disabled
Response time
Configurable - 500 ms default
(Accuracy at 100/200ms - contact Eaton's MTL product line)
LED indicator
Green: power and status indication
Yellow: one provided for channel status
Red: alarm indication
Power requirement, Vs with 20mA signal
60mA at 24V
Power dissipation within unit with 20mA signal
1.4W at 24V
Isolation
Functional isolation channel–channel for safe and hazardous–area
circuits.
Safety description
Refer to certificate for parameters. Um=253V rms or dc
Configurator
A personal computer running MTL PCS45 software with a
PCL45USB serial interface.


Other related product models for MTL4576 as below for your reference.

MTL4501-SR       
MTL4504                
MTL4510              
MTL4510B                
MTL4511
MTL4513             
MTL4514D             
MTL4514_B          
MTL4516                   
MTL4516C
MTL4517             
MTL4521                
MTL4521L            
MTL4523                  
MTL4523L
MTL4523R           
MTL4523V-VL        
MTL4524              
MTL4524S                
MTL4525  
MTL4526             
MTL4541                
MTL4541A            
MTL4541AS              
MTL4541B
MTL4541P           
MTL4541S              
MTL4541T            
MTL4544                  
MTL4544A
MTL4544AS         
MTL4544B               
MTL4544D           
MTL4544S                 
MTL4546
MTL4546C           
MTL4546S              
MTL4546Y            
MTL4549                  
MTL4549C
MTL4549Y           
MTL4573                
MTL4575              
MTL4576-RTD           
MTL4576-THC
MTL4581             
MTL4582B              
MTL4531              
MTL4532                   
MTL4561
MTL4599             
MTL4599N

Do you know where to find MTL4576? Please send me an inquiry!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com






 
Pre:MTL4576-RTD - MTL 4500 Intrinsically Safe Isolators Next:MTL4581 - MTL 4500 Intrinsically Safe Isolators