Production overviews
       
                                 MTL 4500 Intrinsically Safe Isolators  MTL4576-RTD

MTL4576-RTD – MTL5576-RTD TEMPERATURE CONVERTER RTD/potentiometer input, 2-channel The MTLx576–RTD converts signals from resistance temperature detectors (RTDs) mounted in a hazardous area, into 4/20mA currents for driving safe-area loads. Software selectable features include input type and characterisation, ranging, monitoring, testing and tagging. Configuration is carried out using a personal computer. The MTLx576– RTD is compatible with 2– and 3–wire RTD inputs. The MTLx576-RTD can also be configured to drive two safe-area loads from a single input.

                                    



MTL4576-RTD safe isolator product specification
SPECIFICATION
See also common specification
Number of channels
Two
Signal source
2-/3-wire RTDs to BS 60751
Pt 100, Pt 500, Pt 1000
Cu-50 & Cu-53
Ni 100/500/1000 DIN 43760
Location of signal source
Zone 0, IIC, T4–6 hazardous area
Division 1, Group A, hazardous location
Input signal range
0 to 400Ω (0 to 4000Ω Pt & Ni sensors)
Input signal span
10 to 400Ω (10 to 1000Ω Pt & Ni sensors)
RTD excitation current
200µA nominal
Common mode rejection
120dB for 240V at 50Hz or 60Hz
Series mode rejection
40dB for 50Hz or 60Hz
Calibration accuracy (at 20°C)
(includes hysteresis, non-linearity and repeatability)
Input: ± 80mΩ
Output: ± 16µA
Temperature drift (typical)
Input: ± 7mΩ/°C
Output: ± 0.6µA/°C
Example of calibration accuracy and temperature drift
(RTD input)
Span: 250Ω
Accuracy: ± (0.08/250 + 16/16000) x 100%
= 0.13% of span
Temperature drift: ± (0.007/250 x 16000 + 0.6) µA/°C
= ±1.0µA/°C
Safety drive on sensor failure
Upscale, downscale, or off
Output range
4 to 20mA nominal into 300Ω max.
Response time
Configurable - 500 ms default
(Accuracy at 100/200ms - contact MTL)
LED indicator
Green: power and status indication
Yellow: one provided for channel status
Red: alarm indication
Power requirement, Vs with 20mA signal
60mA at 24V
Power dissipation within unit with 20mA signal
1.4W at 24V
Isolation
Functional channel–channel isolation for safe and hazardous–area
circuits
Safety description
Refer to certificate for parameters. Um=253V rms or dc
Configurator
A personal computer running MTL PCS45 software with a
PCL45USB serial interface.


Other related product for MTL4500 range series safe isolators as below.
MTL4501-SR       
MTL4504                
MTL4510              
MTL4510B                
MTL4511
MTL4513             
MTL4514D             
MTL4514_B          
MTL4516                   
MTL4516C
MTL4517             
MTL4521                
MTL4521L            
MTL4523                  
MTL4523L
MTL4523R           
MTL4523V-VL        
MTL4524              
MTL4524S                
MTL4525  
MTL4526             
MTL4541                
MTL4541A            
MTL4541AS              
MTL4541B
MTL4541P           
MTL4541S              
MTL4541T            
MTL4544                  
MTL4544A
MTL4544AS         
MTL4544B               
MTL4544D           
MTL4544S                 
MTL4546
MTL4546C           
MTL4546S              
MTL4546Y            
MTL4549                  
MTL4549C
MTL4549Y           
MTL4573                
MTL4575              
MTL4576-RTD           
MTL4576-THC
MTL4581             
MTL4582B              
MTL4531              
MTL4532                   
MTL4561
MTL4599             
MTL4599N





Do you know where to find MTL4576-RTD? Contact me on line!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com





 
Pre:MTL4575 - MTL 4500 Intrinsically Safe Isolators Next:MTL4576-THC - MTL 4500 Intrinsically Safe Isolators