Good news!Pepperl Fuchs KFD2-STC4-Ex1-Y1 in stock now!
Good news!
Pepperl Fuchs isolated barrier KFD2-STC4-Ex1-Y1 in stock now!
KFD2-STC4-Ex1-Y1
SMART Transmitter Power Supply, Output Current Sink KFD2-STC4-Ex1-Y1
1-channel isolated barrier
24 V DC supply (Power Rail)
Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
Output 0/4 mA ... 20 mA current sink
Terminal blocks with test sockets
Up to SIL 2 acc. to IEC 61508
KFD2-STC4-Ex1-Y1 product specification as below
Need more information for KFD2-STC4-Ex1-Y1 isolated barrier, please feel free to contact us!
Contact details
Pepperl Fuchs isolated barrier KFD2-STC4-Ex1-Y1 in stock now!
KFD2-STC4-Ex1-Y1
SMART Transmitter Power Supply, Output Current Sink KFD2-STC4-Ex1-Y1
1-channel isolated barrier
24 V DC supply (Power Rail)
Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
Output 0/4 mA ... 20 mA current sink
Terminal blocks with test sockets
Up to SIL 2 acc. to IEC 61508
KFD2-STC4-Ex1-Y1 product specification as below
Transfer characteristics | ||
Deviation |
at 20 °C (68 °F), 0/4 ... 20 mA ≤ 10 µA incl. calibration, linearity, hysteresis, loads and fluctuations of supply voltage |
|
Frequency range |
field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 7.5 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 7.5 kHz (-3 dB) |
|
Settling time | 200 µs | |
Rise time/fall time | 20 µs | |
Indicators/settings | ||
Display elements | LED | |
Labeling | space for labeling at the front | |
Directive conformity | ||
Electromagnetic compatibility | ||
Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) | |
Conformity | ||
Electromagnetic compatibility | NE 21:2011 | |
Degree of protection | IEC 60529:2001 | |
Ambient conditions | ||
Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Mass | approx. 200 g | |
Dimensions | 20 x 124 x 115 mm (0.8 x 4.9 x 4.5 inch) , housing type B2 | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-Type Examination Certificate | BAS 99 ATEX 7060 X | |
Marking | II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I | |
Certificate | TÜV 99 ATEX 1499 X | |
Marking | II 3G Ex nA II T4 [device in zone 2] | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 | |
International approvals | ||
UL approval | ||
Control drawing | 116-0428 (cULus) | |
IECEx approval |
IECEx BAS 04.0016X IECEx CML 15.0055X |
|
Approved for |
[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex nA IIC T4 Gc |
Need more information for KFD2-STC4-Ex1-Y1 isolated barrier, please feel free to contact us!