Configuration and RFQ Guide for Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter
Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter is a configured member of the Endress+Hauser Proline Promass F 300 family. The complete extended order code should be retained for quotation and replacement review because process connection, materials, electronics, approvals, calibration and additional options can vary within the family.
Product identity and configuration scope
| Manufacturer | Endress+Hauser |
| Product family | Proline Promass F 300 |
| Product root | 8F3B |
| Extended order code | 8F3B08-BDDBAAAFABSADOSAA2+AADC |
| Measurement principle | Coriolis |
| Measured variables | Mass flow, volume flow, density and temperature, configuration dependent |
| Transmitter format | Compact Proline 300 platform |
| Inquiry purpose | Configured replacement, MRO spare, project supply or nameplate matching |
The 8F3B product root identifies Promass F 300. The characters after the product root form the configured order code. HKXY therefore recommends comparing every character with the installed nameplate and purchase record instead of selecting a replacement from the short family name alone.

Supplied product image for model and nameplate review. Confirm the delivered extended order code, serial number, process connection and approval markings against the purchase requirement.
Promass F 300 family performance context
Endress+Hauser describes Promass F 300 as a Coriolis flowmeter designed for high measurement performance with liquids and gases under demanding process conditions. The measuring principle is independent of fluid viscosity and density, and the device supports multivariable measurement so one measuring point can provide flow, density and temperature data.
| Mass-flow error, liquid | ±0.10% standard; ±0.05% option at family level |
| Volume-flow error, liquid | ±0.10% at family level |
| Mass-flow error, gas | ±0.25% at family level |
| Density error, liquid | ±0.0005 g/cm³ at family level |
| Family measuring range | Up to 2,200,000 kg/h, depending on nominal size and configuration |
| Nominal-size range | DN 8 to DN 250 across the Promass F 300 family |
| Medium-temperature scope | Multiple standard, extended and high-temperature versions are available |
| Installation characteristic | No straight inlet or outlet run is normally required by the measuring principle |
| Diagnostics | Heartbeat Technology and device diagnostics, depending on selected configuration |
These values describe the product family and are not a decoded certificate for this exact extended order code. The final limits for 8F3B08-BDDBAAAFABSADOSAA2+AADC must be taken from its nameplate, calibration documents, ordered options and the applicable Endress+Hauser documentation.
Typical applications and buyer considerations
Promass F 300 instruments are considered for chemical processing, oil and gas, food and beverage, life-science and other process applications that need stable mass-flow and density measurement. Suitability still depends on wetted materials, pressure rating, process connection, temperature, hazardous-area approval, hygiene requirements and communication interface.
For an existing installation, Endress+Hauser 8F3B08-BDDBAAAFABSADOSAA2+AADC Promass F 300 Coriolis Mass Flowmeter should be reviewed together with the piping specification and control-system I/O. A visually similar Promass F 300 can have a different transmitter output, housing, connection, calibration or approval and may not be a drop-in replacement.
Replacement and RFQ checklist
- Send clear front, side and nameplate photographs, including the complete extended order code.
- State the required quantity, condition, destination country and requested delivery date.
- Confirm process medium, expected flow range, pressure and temperature.
- Record nominal size, process connection, wetted material and pressure class.
- Confirm power supply, output or communication protocol and any hazardous-area approval.
- Include calibration, material, inspection and traceability documents required by the project.
Providing these details helps HKXY review the exact configuration, reduce quotation ambiguity and identify whether accessories, documentation or a current equivalent need to be included.
Frequently asked questions
Is 8F3B08 enough to select a replacement?
No. It identifies the product family and size code context, but the complete extended order code and nameplate data are needed to check the configured instrument.
Can Promass F 300 measure liquids and gases?
The Promass F 300 family is designed for liquid and gas measurement. The application range and accuracy for a supplied unit depend on its selected size, calibration and process conditions.
What should be included with an urgent inquiry?
Send the full code 8F3B08-BDDBAAAFABSADOSAA2+AADC, quantity, readable nameplate photos, process conditions, destination and deadline. This is more reliable than sending only the family name.
Manufacturer references