low voltage

Hotline

MTL4541/S REPEATER POWER SUPPLY 4/20mA, HART® for sale now.

description:MTL4541/S – MTL5541/S REPEATER POWER SUPPLY 4/20mA, HART®, 2- or 3-wire transmitters...
BASIC INFO
Production overviews
       
                                 MTL 4500 Intrinsically Safe Isolators  MTL4541

MTL4541/S – MTL5541/S REPEATER POWER SUPPLY 4/20mA, HART®, 2- or 3-wire transmitters The MTLx541 provides a fully-floating dc supply for energising a conventional 2- or 3-wire 4/20mA transmitter, which is located in a hazardous area, and repeats the current in another floating circuit to drive a safe-area load. For HART 2-wire transmitters, the unit allows bi-directional communications signals superimposed on the 4/20mA loop current. Alternatively, the MTLx541S acts as a current sink for a safe-area connection rather than driving a current into the load. Separately powered current sources, such as 4-wire transmitters, can be connected but will not support HART communication.

                                             


MTL4541 safe isolator product specification

SPECIFICATION
See also common specification
Number of channels
One
Location of transmitter
Zone 0, IIC, T4–6 hazardous area if suitably certified
Div. 1, Group A hazardous location
Safe-area output
Signal range: 4 to 20mA
Under/over-range: 0 to 24mA
Safe-area load resistance (MTLx541)
@ 24mA: 0 to 360Ω
@ 20mA: 0 to 450Ω
Safe-area load (MTLx541S)
Current sink: 600Ω max.
Maximum voltage source: 24V dc
Safe-area circuit output resistance: > 1MΩ
Safe-area circuit ripple
< 50µA peak-to-peak
Hazardous-area input
Signal range: 0 to 24mA (including over-range)
Transmitter voltage: 16.5V at 20mA
Transfer accuracy at 20°C
Better than 15µA
Temperature drift
< 0.8µA/°C
Response time
Settles to within 10% of final value within 50µs
Communications supported
HART (terminals 1 & 2 only)
LED indicator
Green: power indication
Maximum current consumption (with 20mA signal)
51mA at 24V
Power dissipation within unit (with 20mA signal)
MTLx541 0.7W @ 24V dc
MTLx541S 1.0W @ 24V dc
Safety description
Terminals 2 to 1 and 3:
Uo=28V Io=93mA Po=651mW Um = 253V rms or dc
Terminals 1 to 3:
Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected
without further certification into any IS loop with an open-circuit
voltage <28V



Other related product models for MTL4541 as below for your reference.
MTL4501-SR       
MTL4504                
MTL4510              
MTL4510B                
MTL4511
MTL4513             
MTL4514D             
MTL4514_B          
MTL4516                   
MTL4516C
MTL4517             
MTL4521                
MTL4521L            
MTL4523                  
MTL4523L
MTL4523R           
MTL4523V-VL        
MTL4524              
MTL4524S                
MTL4525  
MTL4526             
MTL4541                
MTL4541A            
MTL4541AS              
MTL4541B
MTL4541P           
MTL4541S              
MTL4541T            
MTL4544                  
MTL4544A
MTL4544AS         
MTL4544B               
MTL4544D           
MTL4544S                 
MTL4546
MTL4546C           
MTL4546S              
MTL4546Y            
MTL4549                  
MTL4549C
MTL4549Y           
MTL4573                
MTL4575              
MTL4576-RTD           
MTL4576-THC
MTL4581             
MTL4582B              
MTL4531              
MTL4532                   
MTL4561
MTL4599             
MTL4599N


Need more information for MTL4541? Please feel free to send me an inquiry here.
Contact details

HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com








Pre:MTL4526 SWITCH-OPERATED RELAY 2–channel IS–output Next:MTL4541A/AS CURRENT REPEATER 4/20mA passive i/p for HART®