low voltage

Hotline

MTL4582B - MTL 4500 Intrinsically Safe Isolators

description:MTL4582B - MTL5582B RESISTANCE ISOLATOR to repeat RTD signals ...
BASIC INFO
Production overviews
       
                                 MTL 4500 Intrinsically Safe Isolators  MTL4582B

MTL4582B - MTL5582B RESISTANCE ISOLATOR to repeat RTD signals The MTLx582B connects to a 2-, 3-, or 4-wire resistance temperature device (RTD) or other resistance located in a hazardous area, isolates it and repeats the resistance to a monitoring system in the safe area. The module is intended typically (but not exclusively) for use with Pt100 3-wire RTDs. Switches enable selection of 2-, 3-, or 4-wire RTD connection. The MTLx582B should be considered as an alternative, non-configurable MTLx575, for use in RTD applications where a resistance input is preferred or needed instead of 4/20mA. The design is notable for its ease of use and repeatability. The number of wires which can be connected on the safe-area side of the unit is independent of the number of wires which can be connected on the hazardous-area side. The module drives upscale in the case of open circuit detection.

                                                      

MTL4582B safe isolator product specification
SPECIFICATION
See also common specification
Number of channels
One
Location of RTD
Zone 0, IIC, T4 hazardous area
Div. 1, Group A, hazardous location
Resistance source
2-, 3-, or 4-wire* RTDs to BS 1904/DIN 43760 (100Ω at 0°C)
*user selectable by switches (factory set for 3-wire)
Resistance range
10Ω to 400Ω
RTD excitation current
200μA nominal
Output configuration
2, 3 or 4 wires (independent of mode selected for hazardous area
terminals)
Output range
10Ω to 400Ω (from a 100μA to 5mA source)
Temperature drift
±10mΩ/°C typical (0.01%/°C @ 100Ω)
Response time
To within 4% of final value within 1s
Safety drive on open-circuit sensor
Upscale to 420Ω nominal
Transfer accuracy@20°C
<0.15Ω at excitation current 1 - 5mA
<0.25Ω at excitation current 0.5 - 1mA
LED indicator
Green: power indication
Power requirements, Vs
33mA at 24V
35mA at 20V
28mA at 35V
Maximum power dissipation within unit
0.8W at 24V
1.0W at 35V
Safety description
Terminals 1 and 3
Uo = 1.2V Io = 4mA Po = 1.2mW Um = 253V rms or dc
Non-energy-storing apparatus ≤ 1.5V, ≤ 0.1A, ≤ 25mW; can
be connected without further certification into any IS loop with
an open circuit voltage < 5V.
Terminals 1, 3, 4 and 5
Uo = 6.51V Io = 10mA Po = 17mW



Other related product models for MTL4582B as below for your reference.
MTL4501-SR       
MTL4504                
MTL4510              
MTL4510B                
MTL4511
MTL4513             
MTL4514D             
MTL4514_B          
MTL4516                   
MTL4516C
MTL4517             
MTL4521                
MTL4521L            
MTL4523                  
MTL4523L
MTL4523R           
MTL4523V-VL        
MTL4524              
MTL4524S                
MTL4525  
MTL4526             
MTL4541                
MTL4541A            
MTL4541AS              
MTL4541B
MTL4541P           
MTL4541S              
MTL4541T            
MTL4544                  
MTL4544A
MTL4544AS         
MTL4544B               
MTL4544D           
MTL4544S                 
MTL4546
MTL4546C           
MTL4546S              
MTL4546Y            
MTL4549                  
MTL4549C
MTL4549Y           
MTL4573                
MTL4575              
MTL4576-RTD           
MTL4576-THC
MTL4581             
MTL4582B              
MTL4531              
MTL4532                   
MTL4561
MTL4599             
MTL4599N



Where to find 100% original MTL4582B? Call me online!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com











 
Pre:MTL4581 - MTL 4500 Intrinsically Safe Isolators Next:MTL4531 safe isoaltor 1channel vibration probe interface