MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 2-channel

description:MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 2-channel, with line fault detection...
BASIC INFO
Production overviews
       
                                 MTL 5500 Intrinsically Safe Isolators  MTL5516C

MTL4516/C – MTL5516C SWITCH/ PROXIMITY DETECTOR INTERFACE 2-channel, with line fault detection
The MTLx516/C enable two safe-area loads to be controlled by a switch or proximity detector located in a hazardous-area. When selected, open or short circuit conditions in the field wiring are detected by the linefault-detect (LFD) facility and also indicated on the top of the module. Phase reversal for each channel is selected by a switch on the side of the module and output is provided by changeover relay contacts.

                           


MTL5516C product specification
SPECIFICATION
Number of channels :Two
Location of switches
Zone 0, IIC, T6 hazardous area
Div. 1, Group A hazardous
location Location of proximity detector
Zone 0, IIC, T4–6 hazardous area if suitably certified Div. 1, Group A hazardous location Hazardous-area inputs
Inputs conforming to BS EN60947–5–6:2001 standards for proximity detectors (NAMUR)
Voltage applied to sensor
7 to 9V dc from 1kΩ ±10%
Input/output characteristics
Normal phase
Outputs closed if input > 2.1mA (< 2kΩ in input circuit)
Outputs open if input < 1.2mA (> 10kΩ in input circuit)
Hysteresis: 200µA (650Ω) nominal
Line fault detection (LFD) (when selected)
User-selectable via switches on the side of the unit. Line faults are indicated by an LED for each channel. The channel output relay is de-energised if an input line fault is detected.
Open-circuit alarm on if Iin < 50µA
Open-circuit alarm off if Iin > 250µA
Short-circuit alarm on if Rin < 100Ω Short-circuit alarm off if Rin > 360Ω
Note: Resistors must be fitted when using the LFD facility with a contact input 500Ω to 1kΩ in series with switch 20kΩ to 25kΩ in parallel with switch
Safe-area output
Two single-pole relays with changeover contacts Note: reactive loads must be adequately suppressed
Maximum current consumption :35mA at 24V
Power dissipation within unit 0.84W at 24V
LED indicators
Green: power indication Yellow: two: channel status, on when output energised Red: two: LFD indication, on when line fault detected
Safety description (each channel)
Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc
 
Other related product models for MTL5500 range as below for your reference.

MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513 
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V – V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS 
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5991 
MTL5531
MTL5532
MTL5533
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599 




For more question about MTL5516C, please send me an inquiry!
Contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com    Or Cc:
Dianatian118@gmail.com
Website:www.hkxy-lowvoltage.com



 
Pre:MTL5514D 1-channel, dual output, LFD, phase reversal Next:MTL5517 isolator 2 channel DI relay output + LFD alarm