Service decision for ABB 1SDA054884R1 in the approved breaker assembly
ABB 1SDA054884R1 is the order-code reference for this breaker undervoltage release. Its function is to respond to the documented loss-of-supply condition. The common category image is illustrative only; confirm the delivered ABB 1SDA054884R1 by marking and documentation.
Manufacturer identity and key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SDA054884R1 |
| Product family | T4–T6 standard undervoltage releases |
| Component role | breaker undervoltage release |
| Exact ABB order reference | 1SDA054884R1 |
| ABB product series | T4–T6 standard undervoltage releases |
| ABB order code | 1SDA054884R1 |
| ABB manufacturer designation | UVR T4-T5-T6 220..240 Vac - 220..250 Vdc |
| Series grouping | T4–T6 standard undervoltage releases |
| Order-code boundary | Compare each complete code; related versions may not be interchangeable |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The ABB 1SDA054884R1 table identifies the manufacturer designation and the series boundary. Do not read an unspecified contact rating, fit dimension or interchangeability claim into the family name.
Decision path before purchase
- Match ABB 1SDA054884R1 to the installed breaker and drawing revision.
- Check T4–T6 host and listed AC/DC release voltage before approving ABB 1SDA054884R1.
- Compare the full ABB 1SDA054884R1 code with the offered package and the job record.
Electrical interface
For ABB 1SDA054884R1, trace the relevant coil, contact or operator circuit back to the approved schematic. Verify supply type and voltage only where the ABB designation and host manual support them.
Do not energize ABB 1SDA054884R1 solely because a connector fits. Isolation, stored spring energy and control-circuit interlocks need site-approved treatment.
Why the host matters
The ABB 1SDA054884R1 accessory must be selected as part of the breaker assembly, not as a visually similar loose component. Record the host frame, mounting form and existing control arrangement.
Where ABB 1SDA054884R1 is being substituted, check the original assembly documentation and each changed terminal, voltage, contact or mechanical detail.
Receipt and handling
At goods receipt, identify ABB 1SDA054884R1 on the package and component; inspect terminals, molded parts and supplied pieces for damage or mismatch.
Quarantine ABB 1SDA054884R1 if the received code, condition or quantity does not match the purchase request. Keep the discrepancy with the maintenance job record.
Mechanical interface
Check the ABB 1SDA054884R1 fixing position, orientation, travel and protection covers. A change from fixed to withdrawable construction, or from one frame to another, can alter accessory fit.
Before fastening ABB 1SDA054884R1, photograph or record the old position and check the supplied parts against the approved assembly instruction.
Installation sequence
After safe isolation, fit ABB 1SDA054884R1 using the applicable ABB breaker instruction and the site's controlled procedure. Recheck conductors, barriers and enclosure clearances.
For ABB 1SDA054884R1, do not treat an unpowered visual fit as proof of an electrically correct release, contact or mechanism.
Functional acceptance
Once ABB 1SDA054884R1 is fitted, check drop-out, reset and prevention of unsafe reclose. Include both normal operation and the relevant inhibited or fault state in the signed test plan.
Record the ABB 1SDA054884R1 order code, host identity, test conditions and observed results before returning the breaker to service.
Future service record
Keep ABB 1SDA054884R1 beside the host breaker asset number and any voltage or pole restrictions in the spare-parts register.
Future ABB 1SDA054884R1 enquiries should quote the complete manufacturer code; a shortened family label is not a safe purchasing specification.
Handover
Keep the ABB 1SDA054884R1 acceptance record with the equipment history.
Request any later ABB 1SDA054884R1 replacement against the complete code and confirmed host.