ABB 1SFA611524R1001 service handover and specification
ABB 1SFA611524R1001 is the representative identifier for MPEP4 modular emergency-stop operators. The procurement and maintenance notes below describe its documented role as a red pull-release emergency-stop operator, followed by the checks required before it is used at a real site.
Verified technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SFA611524R1001 |
| Product family | MPEP4 modular emergency-stop operators |
| Component role | red pull-release emergency-stop operator |
| Exact ABB order reference | 1SFA611524R1001 |
| ABB product series | MPEP4 modular emergency-stop operators |
| ABB type | MPEP4-10R |
| Actuator diameter | 40 mm |
| Release | Pull |
| Boundary | Safety contact blocks selected separately |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
These ABB 1SFA611524R1001 values apply to the representative only. A related code can change voltage, contacts, dimensions, protocol, approval or rated duty; read its own label before substitution.
Service request
The work request for ABB 1SFA611524R1001 should state the failed function, the existing nameplate and the asset location. The intended application is to build an emergency-stop station with approved contacts. Record the actual circuit or control point so the replacement decision is tied to a specific duty, not to a visual resemblance.
If ABB 1SFA611524R1001 is proposed as a replacement, capture the former unit's complete designation and compare the functions that matter to the operating plant. A family match narrows the search but does not by itself authorize interchange.
Fit and interface
Before ABB 1SFA611524R1001 is installed, compare mechanical dimensions, panel opening or rack position, terminal arrangement, wiring diagram and environmental limits. On a networked product, include the addressing and software dependency review.
For ABB 1SFA611524R1001, document the power supply, connected load or instrument signal at the real interface. Any safety or protection function needs the approved design calculation and competent review.
Order review
For ABB 1SFA611524R1001, the purchasing description needs the complete order reference and the relevant configuration. Check contact blocks, panel fit and safety-category design. Request written clarification whenever a quoted alternative differs in suffix, revision, frame or accessory set.
The buyer should keep ABB 1SFA611524R1001 separate from service kits and companion accessories. Confirm quantity, mounting hardware, connection method and any software or configuration deliverable before issuing the order.
Incoming inspection
When ABB 1SFA611524R1001 arrives, compare the box, device marking and paperwork with the purchase order. Look for shipping damage, missing parts, changed terminal layout or a different revision. Isolate a discrepant item until engineering resolves it.
Photograph the ABB 1SFA611524R1001 marking and preserve its traceability. A shared reference image on a website is not proof that a particular delivered unit has the same electrical rating or options.
Commissioning record
Qualified personnel should install ABB 1SFA611524R1001 under the site's isolation and permit procedure. After wiring or assembly, validate stop, reset and fault response. Record the test conditions, result and any setting changed from the approved baseline.
The release to service for ABB 1SFA611524R1001 requires a successful functional test of the complete circuit, not just a powered indicator. Resolve unexpected alarms, communications or mechanical behavior before handover.
Next maintenance cycle
Retain the final ABB 1SFA611524R1001 order code, drawings, settings and acceptance results with the asset history. This lets the next team distinguish an approved replacement from a superficially similar variant.
If ABB 1SFA611524R1001 later becomes unavailable, reassess the MPEP4 modular emergency-stop operators alternatives against the same service request. Do not assume that the next code in a catalog is a drop-in substitute.
Handover condition
Accept ABB 1SFA611524R1001 only when the exact identity, installation interface and test record all agree.
Keep the approved ABB 1SFA611524R1001 documentation with the equipment record for later troubleshooting and purchasing.