ABB 1SFA619500R1071 Procurement Review: compact twist-release emergency-stop device, Ratings and Series Variants

description:Technical identification and selection guidance for ABB 1SFA619500R1071, including verified family data, system compatibility and configuration checks....
BASIC INFO

ABB 1SFA619500R1071 service handover and specification

ABB 1SFA619500R1071 is the representative identifier for CE3T compact emergency-stop operators. The procurement and maintenance notes below describe its documented role as a compact twist-release emergency-stop device, followed by the checks required before it is used at a real site.

Verified technical data

Technical itemVerified value / selection note
Complete designation1SFA619500R1071
Product familyCE3T compact emergency-stop operators
Component rolecompact twist-release emergency-stop device
Exact ABB order reference1SFA619500R1071
ABB product seriesCE3T compact emergency-stop operators
ABB typeCE3T-10R-11
ActuatorRed emergency-stop mushroom
ReleaseTwist; confirm supplied contact arrangement
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

These ABB 1SFA619500R1071 values apply to the representative only. A related code can change voltage, contacts, dimensions, protocol, approval or rated duty; read its own label before substitution.

Order review

For ABB 1SFA619500R1071, the purchasing description needs the complete order reference and the relevant configuration. Check risk assessment, contact structure and reset behavior. Request written clarification whenever a quoted alternative differs in suffix, revision, frame or accessory set.

The buyer should keep ABB 1SFA619500R1071 separate from service kits and companion accessories. Confirm quantity, mounting hardware, connection method and any software or configuration deliverable before issuing the order.

Service request

The work request for ABB 1SFA619500R1071 should state the failed function, the existing nameplate and the asset location. The intended application is to provide an emergency-stop command in a validated safety circuit. Record the actual circuit or control point so the replacement decision is tied to a specific duty, not to a visual resemblance.

If ABB 1SFA619500R1071 is proposed as a replacement, capture the former unit's complete designation and compare the functions that matter to the operating plant. A family match narrows the search but does not by itself authorize interchange.

Incoming inspection

When ABB 1SFA619500R1071 arrives, compare the box, device marking and paperwork with the purchase order. Look for shipping damage, missing parts, changed terminal layout or a different revision. Isolate a discrepant item until engineering resolves it.

Photograph the ABB 1SFA619500R1071 marking and preserve its traceability. A shared reference image on a website is not proof that a particular delivered unit has the same electrical rating or options.

Fit and interface

Before ABB 1SFA619500R1071 is installed, compare mechanical dimensions, panel opening or rack position, terminal arrangement, wiring diagram and environmental limits. On a networked product, include the addressing and software dependency review.

For ABB 1SFA619500R1071, document the power supply, connected load or instrument signal at the real interface. Any safety or protection function needs the approved design calculation and competent review.

Next maintenance cycle

Retain the final ABB 1SFA619500R1071 order code, drawings, settings and acceptance results with the asset history. This lets the next team distinguish an approved replacement from a superficially similar variant.

If ABB 1SFA619500R1071 later becomes unavailable, reassess the CE3T compact emergency-stop operators alternatives against the same service request. Do not assume that the next code in a catalog is a drop-in substitute.

Commissioning record

Qualified personnel should install ABB 1SFA619500R1071 under the site's isolation and permit procedure. After wiring or assembly, validate the complete safety function. Record the test conditions, result and any setting changed from the approved baseline.

The release to service for ABB 1SFA619500R1071 requires a successful functional test of the complete circuit, not just a powered indicator. Resolve unexpected alarms, communications or mechanical behavior before handover.

Handover condition

Accept ABB 1SFA619500R1071 only when the exact identity, installation interface and test record all agree.

Keep the approved ABB 1SFA619500R1071 documentation with the equipment record for later troubleshooting and purchasing.

 

 