| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SVR405600R1000 |
| Product family | CR-P024DC1 |
| Component role | 24 V DC plug-in interface relay with one changeover |
| Full designation | 1SVR405600R1000 |
| Product family | CR-P024DC1 |
| Coil | 24 V DC |
| Output | 1 changeover (SPDT), 250 V / 16 A |
| Contact | AgNi; relay has no built-in LED |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
Read the ABB 1SVR405600R1000 values with the cited manufacturer publication and delivered marking; option-dependent ratings require confirmation at the site.
Interface inventory
List every ABB 1SVR405600R1000 mechanical and electrical interface: mounting, terminal, supply, contact arrangement, communication setting or fuse arrangement as applicable.
A visually similar part may not fit the ABB 1SVR405600R1000 role. Record the relevant circuit values and dimensions, then resolve mismatches before an outage window is booked.
Position in the system
ABB 1SVR405600R1000 is specified to switch an approved control signal through the matched relay socket. Identify its physical location and functional purpose on the as-built drawing before treating any replacement as equivalent.
When buying ABB 1SVR405600R1000, state the connected equipment, quantity and the reason for replacement. The short family label alone does not establish the required option or mounting fit.
What the order must contain
Use the complete ABB 1SVR405600R1000 marking on the purchase request. Compare the delivered label with the approved bill of materials and retain photographs of any suffix, approval or revision.
For ABB 1SVR405600R1000, check socket pinout, coil polarity, contact load and suppression. Where the surrounding assembly is safety-related, a qualified site engineer must approve the assembled function, not merely the appearance of the part.
Receipt inspection
At receipt, inspect ABB 1SVR405600R1000 packaging and the exact manufacturer code. Confirm supplied accessories, contact or light blocks, terminal base, license and mounting parts where they are separately ordered.
If ABB 1SVR405600R1000 arrives with a different finish, voltage, operator behavior or frame size, hold it for engineering review; do not infer a valid substitution from a similar photograph.
Work package
Before ABB 1SVR405600R1000 is removed or installed, follow the site's isolation and stored-energy procedure. Preserve the original wiring map, configuration file or fuse selection evidence where applicable.
Label ABB 1SVR405600R1000 connections, protect exposed terminals and keep the removed component until the acceptance record confirms correct operation.
Commissioning evidence
After fitting ABB 1SVR405600R1000, measure pickup, dropout and changeover continuity. Record the test conditions and the observed results against the approved design.
The ABB 1SVR405600R1000 acceptance record should cover both normal operation and a controlled fault or off-state where relevant. Return the asset to service only after the responsible person signs off.
Future spare decision
File the ABB 1SVR405600R1000 product identity, installation photo and verified tests with the equipment record so the next buyer can reproduce this decision.
When the ABB 1SVR405600R1000 family is updated, ask the supplier to identify the revised order code and document differences in fit, voltage, contacts, software and approvals.
Release note
Confirm the complete ABB 1SVR405600R1000 code, host fit and accepted functional test before closing the purchase or maintenance job.
Retain the ABB 1SVR405600R1000 manufacturer reference and final as-left record with the asset.