Application boundary for ABB 1YMB760739M4811
ABB 1YMB760739M4811 is the exact order reference for 7.2 kV 200 A CMF fuse-link in the CMF medium-voltage fuse-links family. Its intended job is to protect a correctly engineered MV circuit. Select it against the installed asset rather than a code prefix or a similar-looking component.
The shared ABB category image is only a visual reference, not a verified photograph of the exact ABB 1YMB760739M4811. Confirm the label, full suffix and manufacturer's drawing before procurement.
Technical data to place on the purchase record
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1YMB760739M4811 |
| Product family | CMF medium-voltage fuse-links |
| Component role | 7.2 kV 200 A CMF fuse-link |
| Exact ABB order reference | 1ymb760739m4811 |
| ABB product series | CMF medium-voltage fuse-links |
| ABB fuse name | CMF |
| Representative voltage | 7.2 kV |
| Representative current | 200 A |
| Breaking capacity | 63 kA ABB catalog entry |
| Related boundary | Other listed CMF codes have different voltage/current ratings |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The ABB 1YMB760739M4811 data above identifies the cited variant. Where a related item differs in rating, interface, mechanical position or supplied accessories, the value shown for ABB 1YMB760739M4811 must not be transferred to that other code.
Selection gates
For ABB 1YMB760739M4811, compare voltage, current, striker, dimensions and fuse coordination. Review the complete nameplate and ABB service record, including ratings that a short catalog description may not show.
If a supplier proposes another code in place of ABB 1YMB760739M4811, require a written equivalence decision for each gate. Similar catalog names alone do not prove safe interchangeability.
Where the part belongs
Locate ABB 1YMB760739M4811 in the specific panel, robot or measurement system. Document the host's designation and serial or drawing reference. The application is to protect a correctly engineered MV circuit.
An ABB 1YMB760739M4811 request without the host identity can select the correct-looking family yet the wrong version. Record the installed mounting and mating parts before a quote is approved.
Failure evidence and spare strategy
Before replacing ABB 1YMB760739M4811, capture the fault symptom, alarm history and as-found condition. Check upstream supply, downstream wiring and surrounding mechanism as relevant.
Keep ABB 1YMB760739M4811 as a controlled spare tied to its host and revision. A failed surrounding assembly can make an undamaged replacement appear defective if the original fault remains.
Electrical or mechanical interface
The connection around ABB 1YMB760739M4811 may include a rail, connector, pinion, gland, conductor or control circuit. Record its size, orientation and installation constraints.
Match the ABB 1YMB760739M4811 interface to the field drawing. Unexpected terminal numbers, colour, physical length or protection option are reasons to pause installation and confirm the complete article.
Receipt and fitting
Inspect the delivered ABB 1YMB760739M4811 marking, condition and package contents against the purchase record. Isolate and secure the host following the manufacturer's procedure before handling it.
During ABB 1YMB760739M4811 installation, preserve wiring identification, mechanical clearances, earthing and any required calibration or configuration. Do not infer a replacement route from visual similarity.
Commercial clarification
Quote ABB 1YMB760739M4811 exactly and specify quantity, destination asset, delivery condition and documentation required. Ask for the precise article, not a generic series label.
For ABB 1YMB760739M4811, obtain confirmation of any end-of-life status, replacement code or missing accessory before issuing the purchase order. Preserve that decision with the asset record.
Acceptance evidence
After installing ABB 1YMB760739M4811, verify installed fuse identity and continuity. Record measurements and test states, including the host's normal, fault and inhibited responses where applicable.
Release the equipment only when ABB 1YMB760739M4811 and its connected system pass the site acceptance plan. Retain the as-left code, settings and observations for the next maintenance event.
Other configurations represented on this page
The following codes are grouped with ABB 1YMB760739M4811 by the stated concrete series. They will not receive separate pages. Their different ratings, physical roles or accessories still require individual order confirmation; they are not automatically interchangeable.
- 1YMB760741M4811
- 1YMB760742M4811
- 1YMB761233M4811
- 1YMB761238M4811
Information to send with the enquiry
Send ABB 1YMB760739M4811, the asset identifier, a readable installed label and the technical selection gates to the supplier. Ask for the exact supplied code and any explicit deviation.
File the ABB 1YMB760739M4811 approval and commissioning results with the plant spare-parts record.
ABB 1YM visually similar order-code references
These strings are collected by their similar printed ordering-code format. They may identify different device types, electrical ratings or accessories. Listing them together does not mean they share a product series, function, approval or interchangeability. Confirm the exact ABB designation and manufacturer documentation before ordering or substitution.
1YMB531 references
- 1YMB531030M0002 MF 12kV 100A 442/87mm S
1YMB711 references
- 1YMB711227M4612
- 1YMB711231M4612
- 1YMB711235M4612
- 1YMB711721M2512
1YMB712 references
- 1YMB7124-24M4512
1YMB760 references
- 1YMB760739M4811
- 1YMB760741M4811
- 1YMB760742M4811
1YMB761 references
- 1YMB761233M4811
- 1YMB761238M4811