This practical Q&A explains where ABB 2CSR245140R1164 fits, what must be checked and how to retain an auditable product selection.
Technical data for the exact order code
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 2CSR245140R1164 |
| Product family | DS201 L C16 A30 |
| Component role | DS201 L Type-A RCBO |
| Exact ABB order code | 2CSR245140R1164 |
| ABB catalog type | DS201 L C16 A30 |
| Overcurrent | C16 |
| Residual response | Type A, 30 mA |
| Device family | DS201 L |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
For ABB 2CSR245140R1164, confirm any version-dependent value from its ABB source and delivered marking before use.
What is the exact component?
ABB 2CSR245140R1164 is the full purchase identity for this DS201 L Type-A RCBO. Confirm the complete code on the delivered marking and the approved parts drawing.
The shared image for ABB 2CSR245140R1164 illustrates the product family only. It cannot confirm the precise current, contact, key, voltage or terminal configuration.
How is acceptance demonstrated?
Commission ABB 2CSR245140R1164 using the equipment's approved procedure and qualified personnel. Test the commanded operation, return state and any alarm or safety signal.
Specifically for ABB 2CSR245140R1164, test overcurrent and residual protection. Keep the measured or observed result with the asset record.
When does this configuration fit?
Use ABB 2CSR245140R1164 where the designed task is to protect a final circuit with Type-A earth-fault sensing. Define both the normal state and the protective or off state before selection.
Check ABB 2CSR245140R1164 against neutral wiring, residual type and breaking level. Ratings and mechanical interfaces must match the installed circuit, not just the catalog family name.
What does it connect to?
Trace ABB 2CSR245140R1164 into the rest of the assembly: power path, control supply, host breaker, socket, controller or terminal block as applicable. Record each mating part.
For ABB 2CSR245140R1164, inspect mounting clearance, wiring diagrams and permitted accessories. A visually similar version may connect differently.
What would a mismatch cause?
If ABB 2CSR245140R1164 has the wrong current, coil, curve, residual-current type or contact logic, the equipment may not behave as intended. Review the failure mode before substitution.
Do not treat a related ABB 2CSR245140R1164 family code as automatically interchangeable. Preserve the exact configuration and test evidence.
What goes on the purchase record?
Specify ABB 2CSR245140R1164 in full, with its ABB reference, required companions and any approved replacement decision. Review availability and lifecycle status for the order date.
A complete ABB 2CSR245140R1164 record prevents a later maintenance team from selecting a superficially similar variant with a different function.
Record the outcome
Accept ABB 2CSR245140R1164 only when exact identity, intended duty, companion parts and operating checks agree.
File the ABB 2CSR245140R1164 test outcome and manufacturer reference with the as-built documentation.