ABB A16-30-01-220VAC field identification and technical fit
ABB A16-30-01-220VAC is documented here as an exact equipment reference for selection, changeover and service. Confirm the full label and application before treating another code as equivalent.
Technical data and selection boundary
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | A16-30-01-220VAC |
| Product family | A16 |
| Component role | three-pole A16 contactor with 220 V AC coil reference |
| Family | A16-30-01 |
| Main contacts | 3 normally open |
| Auxiliary contact | 1 normally closed |
| Coil | 220–230 V 50 Hz / 230–240 V 60 Hz catalog version; verify nameplate |
| ABB catalog reference | 1SBL181001R8001 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The verified ABB information for A16-30-01-220VAC is shown above. Values tied to a series or catalog configuration still need to be checked against the supplied unit and its current documentation.
Asset match
ABB A16-30-01-220VAC should be matched to a specific asset tag, duty and installed hardware revision. Record why the part is needed and capture a clear nameplate image before requesting an offer.
For A16-30-01-220VAC, the order description is only one checkpoint. The approved drawings and actual installation determine which connection, control and protection details must be retained.
Functional role
Use A16-30-01-220VAC to switch the assigned motor or power circuit. Confirm the operational sequence and the equipment connected to it so a superficially similar series member is not accepted as an automatic replacement.
If A16-30-01-220VAC is part of a safety, motor or process control function, review the complete system response rather than checking the isolated component alone.
Interfaces to compare
Before ordering A16-30-01-220VAC, verify coil frequency, AC-3 duty, overload coordination and terminal size. Compare terminals, mount, supply, accessories and revision with the installed unit and current ABB documentation.
An alternative to A16-30-01-220VAC should not be released until the engineering owner has documented each changed interface and the required approval.
Removal and preparation
Prepare the work around A16-30-01-220VAC using the site's isolation, lockout and permit rules. Save settings, wiring photographs and diagnostics before removing the existing item.
For A16-30-01-220VAC, reserve the necessary panel space, access to terminals and any separately ordered shaft, base, connector or protection accessory.
Receipt and identification
At receipt, compare the shipped A16-30-01-220VAC label, suffix, order code and hardware build with the approved purchase request. Inspect for handling damage and missing accessories.
Hold A16-30-01-220VAC from installation if coil voltage, release, fiber type, contact arrangement or approval differs from the intended specification.
Commissioning evidence
After installing A16-30-01-220VAC, prove pickup, drop-out and auxiliary indication. Use the manufacturer's procedure and a site-approved test plan; do not energize a connected load simply to identify an unknown variant.
Record the as-left settings, test observations, date and approver for A16-30-01-220VAC. Remove any temporary bypass and restore normal alarms before handover.
Handover and spares
File the ABB A16-30-01-220VAC purchase identity with the asset record, drawing revision and maintenance notes. This keeps future enquiries tied to the actual installed configuration.
Monitor A16-30-01-220VAC during its first operating period for unexpected trips, heating, I/O faults or abnormal switching and resolve deviations through the normal change process.
Same-series reference codes
The following A16 codes can be raised with an ABB A16-30-01-220VAC enquiry. Different suffixes can change ratings, contacts, approvals or fit; do not assume interchangeability.
No additional unassigned A16 code is grouped with A16-30-01-220VAC at this time.
Request-for-quote details
Quote ABB A16-30-01-220VAC exactly, with the asset tag, installed label, required quantity and commissioning constraints. Ask the supplier to state any deviation explicitly.
Keep the final A16-30-01-220VAC approval and inspection record with the plant spare-parts file.