low voltage

Hotline

ABB ACS143-2K1-3 Acs140-Family Compact Ac Drive — Connections, Function and Acceptance

description:Technical identification and selection guidance for ABB ACS143-2K1-3, including verified family data, system compatibility and configuration checks....
BASIC INFO

ABB ACS143-2K1-3 field identification and technical fit

ABB ACS143-2K1-3 is documented here as an exact equipment reference for selection, changeover and service. Confirm the full label and application before treating another code as equivalent.

Technical data and selection boundary

Technical itemVerified value / selection note
Complete designationACS143-2K1-3
Product familyACS143
Component roleACS140-family compact AC drive
Type codeACS143-2K1-3
SupplyThree-phase 380–480 V AC family table
Motor power1.1 kW nominal motor table entry
Output current2.8 A at 4 kHz nominal table entry
StatusLegacy ACS140-family equipment; verify service availability
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The verified ABB information for ACS143-2K1-3 is shown above. Values tied to a series or catalog configuration still need to be checked against the supplied unit and its current documentation.

Asset match

ABB ACS143-2K1-3 should be matched to a specific asset tag, duty and installed hardware revision. Record why the part is needed and capture a clear nameplate image before requesting an offer.

For ACS143-2K1-3, the order description is only one checkpoint. The approved drawings and actual installation determine which connection, control and protection details must be retained.

Interfaces to compare

Before ordering ACS143-2K1-3, verify motor current, supply, braking, control terminals and parameter backup. Compare terminals, mount, supply, accessories and revision with the installed unit and current ABB documentation.

An alternative to ACS143-2K1-3 should not be released until the engineering owner has documented each changed interface and the required approval.

Functional role

Use ACS143-2K1-3 to regulate speed on the approved small motor. Confirm the operational sequence and the equipment connected to it so a superficially similar series member is not accepted as an automatic replacement.

If ACS143-2K1-3 is part of a safety, motor or process control function, review the complete system response rather than checking the isolated component alone.

Removal and preparation

Prepare the work around ACS143-2K1-3 using the site's isolation, lockout and permit rules. Save settings, wiring photographs and diagnostics before removing the existing item.

For ACS143-2K1-3, reserve the necessary panel space, access to terminals and any separately ordered shaft, base, connector or protection accessory.

Commissioning evidence

After installing ACS143-2K1-3, compare speed demand, current and fault response. Use the manufacturer's procedure and a site-approved test plan; do not energize a connected load simply to identify an unknown variant.

Record the as-left settings, test observations, date and approver for ACS143-2K1-3. Remove any temporary bypass and restore normal alarms before handover.

Receipt and identification

At receipt, compare the shipped ACS143-2K1-3 label, suffix, order code and hardware build with the approved purchase request. Inspect for handling damage and missing accessories.

Hold ACS143-2K1-3 from installation if coil voltage, release, fiber type, contact arrangement or approval differs from the intended specification.

Handover and spares

File the ABB ACS143-2K1-3 purchase identity with the asset record, drawing revision and maintenance notes. This keeps future enquiries tied to the actual installed configuration.

Monitor ACS143-2K1-3 during its first operating period for unexpected trips, heating, I/O faults or abnormal switching and resolve deviations through the normal change process.

Same-series reference codes

The following ACS143 codes can be raised with an ABB ACS143-2K1-3 enquiry. Different suffixes can change ratings, contacts, approvals or fit; do not assume interchangeability.

No additional unassigned ACS143 code is grouped with ACS143-2K1-3 at this time.

Request-for-quote details

Quote ABB ACS143-2K1-3 exactly, with the asset tag, installed label, required quantity and commissioning constraints. Ask the supplier to state any deviation explicitly.

Keep the final ACS143-2K1-3 approval and inspection record with the plant spare-parts file.

 

 

Pre:Before Replacing ABB AF145-30-11: Af145 Three-Pole Electronic-Coil Contactor and Verification Points Next:Specify ABB CA5-22N, 1SBN010040R1222 Four-Contact Contactor Auxiliary Block for the Correct Plant Asset