low voltage

Hotline

ABB ACS180-04S-09A4-4 | 4 kW, 9.4 A and 400 V Three-Phase Motor Control

description:Technical identification and selection guidance for ABB ACS180-04S-09A4-4, including verified family data, system compatibility and configuration checks....
BASIC INFO

ACS180-04S-09A4-4 drive selection: current, load duty and machine integration

The ABB ACS180-04S-09A4-4 is an IP20 machinery drive with a 4 kW IEC nominal output rating and 9.4 A rated current for the 400 V class. The full designation is important when checking a replacement because frame, supply and current variants are not interchangeable by family name alone.

Key technical data

Technical itemVerified value / selection note
Type designationACS180-04S-09A4-4
Nominal IEC output power4 kW
Rated output current9.4 A
Nominal supply class400 V three-phase family
Frame / enclosureR1; IP20
Drive familyABB ACS180 machinery drive
Exact application ratingCheck overload duty, ambient derating and full nameplate

The table summarizes family or catalog values for identification and initial selection. Confirm the nameplate, environmental limits, standards, revision and options for the exact device before procurement or engineering approval.

Application and system selection

Match the drive to motor nameplate current and the machine’s torque profile across its operating range. Conveyors, mixers and pumps can require different overload capability, acceleration ramps and braking arrangements. Confirm starts per hour, low-speed cooling, required speed range and the available supply before selecting a unit.

Configuration and compatibility

Review the exact ACS180 code, EMC requirements, control I/O, fieldbus and safety functions against the machine design. Verify upstream protection and short-circuit coordination using ABB’s current documentation. A nominal kilowatt match does not establish suitability if ambient conditions, overload, carrier frequency or motor cable length differ.

Related models and order-code references

The following designations are related catalog references, not automatic substitutes. Check each complete code, rating, connection, revision and application requirement before selecting a variant.

  • ACS180-04N-03A3-4
  • ACS180-04N-25A0-4
  • ACS180-04S-03A3-4
  • ACS180-04S-04A0-4
  • ACS180-04S-05A6-4
  • ACS180-04S-12A6-4
  • ACS180-04S-17A0-4
  • ACS180-04S-25A0-4

Installation and commissioning

Install with the specified orientation and cooling clearances, bond protective earth and route motor/control cables according to the drive manual. Observe DC-link discharge requirements before service. At commissioning, enter motor data, verify command and reference sources, test direction, ramps and stop behavior, then record parameters and alarms.

Replacement and procurement information

For a quotation or replacement review, provide the complete designation ACS180-04S-09A4-4, the order code where applicable, serial or hardware revision, quantity, operating environment, connected equipment and required delivery date. Include a legible nameplate image and relevant wiring, loop or switchgear drawing so the exact interface and configuration can be checked.

Ask the supplier to confirm accessories, revision compatibility and any approved successor in writing. Do not select solely from a family name or product photograph. Follow the current ABB installation and safety instructions for the exact unit.

 

 

Pre:ABB 1VC1AM00014090, VD4/P 12.12.25-NS Medium-Voltage Vacuum Circuit Breaker | 12 kV Class, 1250 A and 25 kA Reference Configuration Next:ABB ACS380-03E-15A6-4 | 15.6 A, 380–480 V Three-Phase Supply and Machine Integration