low voltage

Hotline

ABB EF19-2.7 Electronic Motor Overload Relay: Order Identity, Technical Data and Fit Review

description:Technical identification and selection guidance for ABB EF19-2.7, including verified family data, system compatibility and configuration checks....
BASIC INFO

EF19-2.7: what the order code must match

EF19-2.7 is a electronic motor overload relay for a defined industrial installation. When requesting EF19-2.7, keep its complete printed designation, hardware revision and project context together so that purchasing and engineering review the same component.

Technical identification and selection data

Technical itemVerified value / selection note
Complete designationEF19-2.7
Product familyEF19
Component roleelectronic motor overload relay
Current adjustment0.80 to 2.7 A
Trip classes10E, 20E or 30E selectable
Order code1SAX121001R1103
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

The EF19-2.7 data above identifies the published function and key selection checks. A rating or connection shared with another device does not establish an approved replacement for EF19-2.7.

Match the interface before ordering

The critical cross-check for EF19-2.7 is: Match motor nameplate current, contactor frame, trip class and reset philosophy. A similar product outline, series name or current class alone is not enough.

Ask the supplier to identify any deviations from EF19-2.7 in connection hardware, function, approvals and accessories. Resolve them against the engineering drawing before accepting a substitute.

Where this item works

For EF19-2.7, the intended duty is: Protect a compatible motor starter against sustained overload and phase-loss conditions. Capture the actual connected load or signal, site environment and operating sequence before purchase.

The installation record for EF19-2.7 should include a nameplate photograph, panel drawing and the failed unit's setting or software version when applicable.

Installation and return-to-service proof

For EF19-2.7, the controlled acceptance method is: Set the current and class, then confirm trip contacts, alarm and restart control under a supervised test. Record the actual results, not merely a pass/fail impression.

Before returning the equipment containing EF19-2.7 to production, verify isolation, protective coordination, terminal identification and any interlock or safety-related response.

Same-series ordering references

These codes share the EF19 grouping with EF19-2.7, but option strings can alter ratings, wiring, firmware or certifications. They are not automatically interchangeable with EF19-2.7.

  • EF19-6.3

Buyer handover record

Quote EF19-2.7 in full, state quantity and destination, and attach the relevant panel photograph and drawing. Confirm whether accessories are included in the offered supply.

At receipt, compare the supplied label with EF19-2.7 and document any difference before installation. Retain the final part identity and the EF19-2.7 acceptance test with the asset history.

 

 

Pre:ABB CR-M024DC4 Plug-In Miniature Interface Relay — Selection Evidence and Site Acceptance Next:Specify ABB SH203-C10 — Three-Pole C-Curve Miniature Circuit Breaker with Interface and Commissioning Notes