Field-fit and commissioning guide for ESB100-20N-06 (1SAE361111R0620)
Use the complete ESB100-20N-06 (1SAE361111R0620) designation when requesting this installation contactor for controlled loads. The installation must be checked against the actual equipment marking, because a shared product family does not establish identical ratings, options or approvals.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | ESB100-20N-06 (1SAE361111R0620) |
| Product family | ESB100 |
| Component role | installation contactor for controlled loads |
| Contacts | 2 NO for ESB100-20N-06 |
| Rated AC-1 current | 100 A family designation; confirm duty |
| Control supply | 230 V AC/DC for -06 variant |
| Order code | 1SAE361111R0620 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
This table identifies the published family facts for ESB100-20N-06 (1SAE361111R0620). Treat any unlisted option as a selection question, not as an implied specification for ESB100-20N-06 (1SAE361111R0620). Consult the current ABB data and the installed nameplate before release.
What the device does
The work assigned to ESB100-20N-06 (1SAE361111R0620) is specific: Switch the assigned building or industrial load from the panel control circuit. Record the controlled process, feeder or network point in which ESB100-20N-06 (1SAE361111R0620) operates.
Check the upstream source and the downstream load or signal as a complete path. For ESB100-20N-06 (1SAE361111R0620), an apparently matching connector or housing does not establish functional equivalence.
Match the ordered configuration
The most important purchase question for ESB100-20N-06 (1SAE361111R0620) is: Check pole arrangement, utilization category, coil voltage, enclosure heat and connected load; ESB100-40N is not the same contact arrangement. Record any missing suffix, revision, calibration or approval with the supplier.
Ask whether the offered ESB100-20N-06 (1SAE361111R0620) item includes the required terminals, accessories and documentation. Any suggested substitute needs a line-by-line comparison, not an assumption based on the family prefix.
Installation boundary
Before fitting ESB100-20N-06 (1SAE361111R0620), isolate the process or electrical system under the site procedure and check the drawing, connection, mounting and environmental limits.
Document the original terminals and settings for ESB100-20N-06 (1SAE361111R0620). Reapply only approved wiring and parameter changes; retain the previous unit identification for traceability.
Commissioning evidence
The practical acceptance check for ESB100-20N-06 (1SAE361111R0620) is: Test coil pickup and dropout, contact continuity and feedback interlocks with the circuit isolated appropriately. Capture actual readings, states or faults rather than reporting only that the device powered up.
Close the work order for ESB100-20N-06 (1SAE361111R0620) with the observed test result, final configuration and responsible reviewer. If a safety or protective function is involved, follow the site-specific validation procedure.
Other codes within this series
The following ESB100 designations are grouped on the ESB100-20N-06 (1SAE361111R0620) page to aid searches and enquiries. They may differ in rating, options, protocol or dimensions. Confirm each full designation before substitution.
- ESB100-20N-06, 1SAE361111M0620
- ESB100-40N-06 (1SAE661111R0640)
Enquiry details to send
Quote ESB100-20N-06 (1SAE361111R0620) exactly, then state the installed equipment, required quantity, delivery location and whether a new unit or an approved service spare is needed.
For ESB100-20N-06 (1SAE361111R0620), request the current datasheet, option confirmation and lead time. On receipt, compare the supplied marking to the approved enquiry and retain the commissioning notes with the equipment record.