ABB F204 AC-40/0.03: Four-Pole Type Ac Residual-Current Breaker Specification for Maintenance Buying

description:Technical identification and selection guidance for ABB F204 AC-40/0.03, including verified family data, system compatibility and configuration checks....
BASIC INFO

F204 AC-40/0.03 in the installed application

The full F204 AC-40/0.03 marking belongs on the enquiry and the receiving inspection. F204 AC-40/0.03 is a four-pole type AC residual-current breaker whose suitability depends on the actual connected process, circuit or control project.

Technical parameters

Technical itemVerified value / selection note
Complete designationF204 AC-40/0.03
Product familyF204 AC
Component rolefour-pole type AC residual-current breaker
Poles4
Rated current40 A
Residual sensitivity30 mA
Residual waveformType AC
Order code2CSF204005R1400
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

Read these F204 AC-40/0.03 parameters together with the nameplate and the manufacturer's option data. The short family label does not establish every rating or installed accessory.

Questions for the quotation

Ask the supplier to confirm this F204 AC-40/0.03 match: Confirm all active conductors pass through the device, the 40 A duty, 30 mA sensitivity and the fault waveform suitability. Attach the installed full code and relevant drawings to the enquiry.

A similar item is not automatically equivalent to F204 AC-40/0.03. Ask for a written comparison of ratings, interfaces, terminals, dimensions, options and required firmware or settings.

Application snapshot

The intended function of F204 AC-40/0.03 is: Detect the specified AC earth leakage on a three-phase circuit with neutral. Record the real process or electrical duty and the equipment that sends or receives the signal.

For F204 AC-40/0.03, note any site condition that changes selection: mounting position, ambient temperature, load profile, supply quality, hazardous-area conditions or the existing communication project.

How to prepare the replacement

Before working on F204 AC-40/0.03, follow the plant's isolation or process-shutdown procedure. Photograph or record terminal positions, accessory parts, settings and current indications.

For F204 AC-40/0.03, compare the delivered identification with the approved order. Fit only the required components and restore an approved backup rather than recreating settings from memory.

What to observe on startup

The acceptance test for F204 AC-40/0.03 is: Run the specified residual-current trip and reset test, and document trip time/current. Compare measured results and indications with the commissioning record.

If F204 AC-40/0.03 forms part of a protective function, verify fault response and reset in addition to normal operation. Keep the final readings and sign-off with the maintenance file.

Other designations in this family

The following F204 AC codes are gathered with F204 AC-40/0.03 for search and purchase enquiries. They can differ in sensor, coil, rating, pole count, communication or accessories. Check each complete code; they are not automatically direct replacements.

No other unassigned F204 AC code is grouped with F204 AC-40/0.03 here.

Receiving checklist

When F204 AC-40/0.03 arrives, compare the marked code, revision and included accessories with the order. Record any variance before the equipment is installed.

Retain the F204 AC-40/0.03 technical document, inspection and commissioning result with the asset record so the next replacement can be matched accurately.

 

 

Pre:ABB F202 AC-25/0.1 Two-Pole Type Ac Residual-Current Breaker | Process Role and Technical Review Next:Site Guide to ABB FEW321.040.A.1.S.1.A1.B.1.B.1.A.2.A.2.A.1.A.1-AC.M5.T3 Watermaster Remote Electromagnetic Flowmeter Selection and Testing