Technical fit record for ABB GFS810, 3BSE093005R1
ABB GFS810, 3BSE093005R1 is indexed here as a specific buying and service reference. Confirm its complete designation before assuming that another family member has the same terminals, electrical duty or approvals.
Verified technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | GFS810, 3BSE093005R1 |
| Product family | GFS810 |
| Component role | Select I/O ground-fault detection module |
| System | Select I/O |
| Function | Ground-fault resistance monitoring |
| Range | 0–1 MΩ |
| Channels | 1 |
| ABB article | 3BSE093005R1 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The table for ABB GFS810, 3BSE093005R1 separates verified family data from the configuration checks that still require a nameplate or ABB order record. Do not use a family rating as an unconditional guarantee for the installed unit.
Site preparation
Plan the GFS810, 3BSE093005R1 replacement under the facility isolation and permit rules. Preserve photographs, configuration files, settings and a diagnostic baseline before disturbing wiring.
Check enclosure temperature, grounding, segregation and protection coordination for GFS810, 3BSE093005R1. Record any accessory that is supplied separately rather than assuming it is in the device box.
Purchase decision
Specify ABB GFS810, 3BSE093005R1 against a particular asset tag and duty. This unit is used to identify ground faults on externally powered field signals; record the intended circuit, process or equipment location before requesting a quote.
For GFS810, 3BSE093005R1, confirm GIO pairing, grounding path, external injection and diagnostic integration. A matching short family name is not sufficient evidence of electrical, mechanical or software interchangeability.
Interface checklist
Before ordering GFS810, 3BSE093005R1, compare the installed terminal or connector arrangement, power source, mounting envelope and ancillary hardware with the current drawing.
Document the serial number and revision of GFS810, 3BSE093005R1 where available. If a supplier proposes a substitute, obtain engineering acceptance for every changed interface.
Lifecycle handover
Keep ABB GFS810, 3BSE093005R1 linked to its exact spares description, drawings and current manual revision. This helps the next maintenance team identify the same configuration rather than a superficially similar item.
Review the first operating period of GFS810, 3BSE093005R1 for alarms, heating, drift or switching anomalies and update the asset record if the installed build differs from the original request.
Receipt inspection
On arrival, compare the supplied GFS810, 3BSE093005R1 label and order code with the approved purchase description. Inspect packaging, terminals, seals and visible damage.
Do not install GFS810, 3BSE093005R1 when the shipped suffix, control voltage, release or approval differs from the approved build; resolve that discrepancy before commissioning.
Commissioning evidence
For GFS810, 3BSE093005R1, test ground continuity and fault indication using the approved procedure. Carry out only the tests approved for this device and the connected installation.
Save the as-left settings, measured results, witness and work-order reference for GFS810, 3BSE093005R1. Any temporary bypass or inhibited alarm must be removed before normal operation.
Related configuration references
The following GFS810 codes are recorded with ABB GFS810, 3BSE093005R1 for enquiry. Suffixes may alter ratings, dimensions, approvals or accessories; these are not automatic replacements.
No additional unassigned GFS810 code is grouped with GFS810, 3BSE093005R1 at this stage.
Information to send with an enquiry
Quote ABB GFS810, 3BSE093005R1 exactly and include the asset tag, electrical or process duty, required accessories and delivery documentation.
For GFS810, 3BSE093005R1, request written confirmation of any deviation from the fitted unit before accepting an alternative.