ABB MS132-0.4 Manual Motor Starter: Technical Data and Commissioning Decisions

description:Technical identification and selection guidance for ABB MS132-0.4, including verified family data, system compatibility and configuration checks....
BASIC INFO

Working with MS132-0.4: function, limits and field checks

MS132-0.4 is the specified manual motor starter. The complete MS132-0.4 designation should remain on the purchase request and maintenance record because a shared family name does not prove interchangeability.

Key technical data for identification

Technical itemVerified value / selection note
Complete designationMS132-0.4
Product familyMS132
Component rolemanual motor starter
Overload setting0.25 to 0.40 A
Poles3
Order code1SAM350000R1003
Trip coordinationVerify feeder short-circuit and contactor data
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

For MS132-0.4, the table records documented type-level facts and flags items that still require an exact order-code or nameplate check. Use those checks before approving a substitute.

Fault-isolation route

If the installed MS132-0.4 appears faulty, first distinguish a component problem from external wiring, power, field devices or configuration. Match the actual motor nameplate current, starter combination, available fault current and accessory contacts.

Record the symptom and the measurement that supports the diagnosis for MS132-0.4. Check the relevant drawings and status indications with the machine in a safe condition; avoid replacing a working device to mask a system fault.

Normal operating duty

MS132-0.4 is intended for this system duty: Protect and manually isolate a small motor feeder within the documented setting range.

Before selecting MS132-0.4, document the actual supply, connected load or signal, operating environment and expected cycle. A similar housing is not evidence of an equal operating envelope.

Replacement and acceptance

A replacement for MS132-0.4 must preserve the documented interfaces and settings. Set the current dial and test trip indication, interlock operation and downstream shutdown.

After work on MS132-0.4, record the installed complete code, observed tests, firmware or setting revision where relevant, and the person approving return to service.

Other codes in the same series

The codes below belong to the MS132 grouping relevant to MS132-0.4. Ratings, interfaces, software, approvals and accessories can differ. They are ordering references, not automatic replacements.

  • 1SAM350000R1001
  • 1SAM350000R1002
  • 1SAM350000R1003
  • 1SAM350000R1004
  • 1SAM350000R1005
  • 1SAM350000R1006
  • 1SAM350000R1007
  • 1SAM350000R1008
  • 1SAM350000R1009
  • 1SAM350000R1010
  • 1SAM350000R1011
  • 1SAM350000R1012
  • 1SAM350000R1013
  • 1SAM350000R1014
  • 1SAM350000R1015
  • MS132-0.63
  • MS132-1.0
  • MS132-1.01SAM350000R1005
  • MS132-1.6
  • MS132-12-HKF1-11
  • MS132-16
  • MS132-16-HKF1-11 ,1SAM350005R1011
  • MS132-2,5 1SAM350000R1007
  • MS132-2.5
  • MS132-2.5 1.6...2.5A
  • MS132-20
  • MS132-25
  • MS132-25-HKF1-11
  • MS132-32
  • MS132-32-HKF1-11
  • MS132-4 1SAM350000R1008
  • MS132-4.0
  • MS132-4.0-HKF1-11
  • MS132-6.3
  • MS132-6.3-HKF1-11

Purchase and handover checklist

Request MS132-0.4 by its full designation. Provide quantity, current nameplate image, site wiring diagram and any required certificates. Ask the supplier to identify deviations from MS132-0.4 explicitly.

Before returning the system containing MS132-0.4 to service, confirm protective devices, terminal assignments, control logic and test records. Retain the final identity of MS132-0.4 in the asset history.

ABB MS visually similar order-code references

These strings are collected by their similar printed ordering-code format. They may identify different device types, electrical ratings or accessories. Listing them together does not mean they share a product series, function, approval or interchangeability. Confirm the exact ABB designation and manufacturer documentation before ordering or substitution.

MS116 1 references

  • MS116 10-16A
  • MS116 1SAM201902R1002
  • MS116 1SAM250000R1002

MS116-0 references

  • MS116-0.4

MS116-1 references

  • MS116-10, 480VAC
  • MS116-12.0 25 кА

MS116-2 references

  • MS116-2.5
  • MS116-25, 1SAM250000R1014

MS116-4 references

  • MS116-4.0-HKF1-11

MS116-6 references

  • MS116-6.3

MS132-0 references

  • MS132-0.4
  • MS132-0.63

MS132-1 references

  • MS132-1.0
  • MS132-1.01SAM350000R1005
  • MS132-1.6
  • MS132-10
  • MS132-10-HKF1-11
  • MS132-12-HKF1-11
  • MS132-16
  • MS132-16-HKF1-11 ,1SAM350005R1011

MS132-2 references

  • MS132-2,5 1SAM350000R1007
  • MS132-2.5
  • MS132-2.5 1.6...2.5A
  • MS132-20
  • MS132-25
  • MS132-25 50кА
  • MS132-25-HKF1-11

MS132-3 references

  • MS132-32
  • MS132-32-HKF1-11

MS132-4 references

  • MS132-4 1SAM350000R1008
  • MS132-4.0
  • MS132-4.0-HKF1-11

MS132-6 references

  • MS132-6.3
  • MS132-6.3-HKF1-11

MS165-3 references

  • MS165-32

MS165-4 references

  • MS165-42
  • MS165-42(1SAM451)
  • MS165-42-1SAM451000R1015

MS165-6 references

  • MS165-63
  • MS165-65 25кА

MS165-7 references

  • MS165-73

MS165-8 references

  • MS165-80

MS165–4 references

  • MS165–42

MS325- references

  • MS325- 25

MS325-1 references

  • MS325-16

MS325-2 references

  • MS325-20

MS325-6 references

  • MS325-6.3 (1SAM150000R1009)

MS325-9 references

  • MS325-9

MS325-H references

  • MS325-HK11

MS325?6 references

  • MS325?690V

MS495-1 references

  • MS495-100 50 кА

 

 

Pre:ABB TB806 in Service — S800 Modulebus Cable Adaptor Interfaces, Settings and Test Plan Next:Replacement Review for ABB SH202-C10 Two-Pole Miniature Circuit Breaker — Compatibility and Verification