Technical service profile for ABB S202M-C16
ABB S202M-C16 should be specified as a complete device, not inferred from a similar family name. Its protection, control or measurement role must match the actual equipment and installation.
Technical data for model selection
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | S202M-C16 |
| Product family | S202M |
| Component role | two-pole S200M miniature circuit breaker |
| Poles | 2 |
| Rated current | 16 A |
| Trip curve | C |
| Order code | 2CDS272001R0164 |
| Variants | DC/accessory suffixes require separate verification |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The stated S202M-C16 data identify the selected reference and its engineering boundaries. Confirm the unit label, applicable standard and exact options before ordering or energizing.
What must match
Check S202M-C16 against voltage type, breaking rating, curve, accessory and cable arrangement. In procurement, ask for photographs or ABB documentation that show the complete designation and terminal configuration.
If the candidate S202M-C16 differs from the installed device, document the difference and obtain an engineering decision before fitment.
Installation controls
Before working on S202M-C16, apply the approved isolation and permit controls. Capture the existing connections, settings and safety functions as a recoverable baseline.
Install S202M-C16 with the correct conductor, panel spacing and environmental protection. Follow the ABB instructions for the specific construction rather than using a generic wiring assumption.
Handover evidence
For S202M-C16, verify circuit mapping and switching of both poles. Record the measured result, witness and date beside the equipment tag.
Retain the final S202M-C16 designation, revision, settings and test outcome in the maintenance record so later work does not rely on memory.
Design intent
The intended duty of S202M-C16 is to protect the designated two-pole 16 A circuit. Mark the circuit, asset or process tag and preserve the plant drawing that governs this function.
Do not assume a different suffix within S202M provides the same duty as S202M-C16; ratings and accessory arrangements can differ.
Fault-finding baseline
For a future fault involving S202M-C16, keep records of upstream supply, load, trip or output state and connected accessories. This separates a device issue from a wiring or process issue.
A replacement S202M-C16 should be checked at the same duty point as the prior installation, with abnormal behavior investigated before return to service.
Related model references
The following S202M codes are indexed with ABB S202M-C16 for search and enquiry. They remain configuration-specific; this grouping does not assert electrical, mechanical or approval interchangeability.
- S202M-B10
- S202M-B6
- S202M-C1
- S202M-C10
- S202M-C2
- S202M-C20
- S202M-C20DC+S2C-H11R+S2CH02R 110VDC
- S202M-C2DC
- S202M-C3
- S202M-C32
- S202M-C3DC
- S202M-C6
- S202M-C6 2CDS272001R0064
Enquiry checklist
Send the exact ABB S202M-C16 designation with circuit or plant tag, required rating, accessories and approval. Confirm current lifecycle and delivery scope.
On receipt of S202M-C16, compare label, package contents and documentation to the approved request. Hold any discrepancy for review before fitting.