ABB SH202M-C6 technical application brief
Use ABB SH202M-C6 as the complete reference for this equipment position. Matching a family name alone does not establish module fit, electrical ratings or permitted service configuration.
Technical parameters and limits
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | SH202M-C6 |
| Product family | SH202M |
| Component role | two-pole SH200M miniature breaker |
| Poles | 2 |
| Rated current | 6 A |
| Trip curve | C |
| Icn | 10 kA family reference |
| Order code | 2CDS272011R0064 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The SH202M-C6 values above are selection checkpoints. Check the fitted nameplate and current ABB installation documents before releasing a replacement or changing field wiring.
Connection evidence
For SH202M-C6, inspect prospective fault, residential/industrial application and busbar. Verify the exact terminals, power path, mechanical keying and software interface against the site drawing.
If a proposed SH202M-C6 has different connectors or ratings, stop the swap and document the engineering decision rather than assuming series compatibility.
Asset purpose
ABB SH202M-C6 is intended to protect the designated two-pole small-load branch. Record the cabinet, circuit or loop tag and the controlled process so the purchase is linked to a defined duty.
A SH202M-C6 replacement request should identify the installed hardware revision and the reason for change, including any active alarm or failed test.
Diagnostic baseline
For later troubleshooting of SH202M-C6, capture supply status, module diagnostics, output state and the relevant process reading. This makes it possible to distinguish a device fault from a field issue.
Compare SH202M-C6 with the pre-change baseline after installation. Investigate unexpected alarms, temperature, noise or switching before returning the asset to normal duty.
Before energizing
Isolate the affected circuit before working on SH202M-C6, following the plant procedure. Preserve wiring photos, parameters and a known-good diagnostic snapshot.
Seat and terminate SH202M-C6 with the specified accessories. Check grounding, segregation and installation environment before power is restored.
Acceptance test
For SH202M-C6, verify wiring and both pole states. Record the result, witness and acceptance date, including any temporary bypass or inhibited alarm that must be removed.
Close the SH202M-C6 work order only when as-left settings and drawings reflect the actual installation.
Other configuration references
These SH202M references are indexed alongside ABB SH202M-C6 for enquiry. Different options, ratings or approvals may apply, so the codes are not automatic substitutes.
No additional unassigned SH202M designation is grouped under SH202M-C6.
Procurement handoff
Quote ABB SH202M-C6 exactly, including the application tag, required accessories, installation conditions and documentation revision.
At receipt, compare the supplied SH202M-C6 against the approved code before fitting. Retain the acceptance evidence with the asset record.