low voltage

Hotline

Specify ABB TA200DU-175 | Thermal Motor-Overload Relay, Interfaces and Site Checks

description:Technical identification and selection guidance for ABB TA200DU-175, including verified family data, system compatibility and configuration checks....
BASIC INFO

TA200DU-175: component role and practical integration notes

TA200DU-175 is the specified thermal motor-overload relay. Specify TA200DU-175 by its complete designation, because visual similarity or a partial family number does not prove electrical or mechanical interchangeability.

Technical identification and selection data

Technical itemVerified value / selection note
Complete designationTA200DU-175
Product familyTA200DU
Component rolethermal motor-overload relay
Setting range130 to 175 A
Trip class10A
Typical pairingCheck compatible contactor frame
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

For TA200DU-175, the table separates confirmed family or type-code facts from items requiring the actual nameplate and installed option record. Do not assume another unit has the same interfaces.

Acceptance and service handover

For the installed TA200DU-175, Test trip indication, auxiliary contacts, reset mode and feeder shutdown against the approved motor-protection design.

Capture the observed behavior, settings, installed revision and fault status of TA200DU-175. Keep those findings with the plant asset record so a later service team can distinguish this exact code from a related option.

Where this component fits

Use TA200DU-175 in the intended system context: Provide motor overload and phase-loss protection as part of a coordinated contactor starter.

Document the equipment served by TA200DU-175, the normal load or signal, the site environment and the reason this component was selected. A replacement must preserve that function, not just fit the available space.

Interface and compatibility route

Before approving TA200DU-175, Set the dial from the actual motor full-load current and check contactor fit, upstream short-circuit device and reset philosophy.

Compare the mating equipment, terminals, wiring diagram, supply, firmware or accessory choices as applicable to TA200DU-175. Resolve every mismatch before a purchase order or installation work package is released.

Same-family ordering references

The following codes share the TA200DU grouping with TA200DU-175. They may differ in rating, wiring, software, safety approval or accessories and are not automatic substitutes.

  • 1SAZ421201R1005 TA200DU-175
  • TA200DU-135 1SAZ421201R1003
  • TA200DU-200
  • TA200DU110
  • TA200DU15

Quotation checklist

Quote TA200DU-175 exactly. Include quantity, nameplate photo, installed hardware revision, drawings and the operating conditions. Ask the supplier to state in writing whether the offered item is the same full code or a separately approved alternative.

Before returning equipment to service with TA200DU-175, confirm protective devices, terminal assignment, safety functions and the accepted test record. Preserve the final code in purchasing and maintenance systems.

 

 

Pre:ABB OT1250E12: Manual Switch-Disconnector Technical Selection Guide Next:ABB TF140DU-110 Thermal Motor-Overload Relay | Ratings, Fit and Commissioning