X20CP1485 selection record: celeron x20 plc with modular interface and installed-system fit
X20CP1485 belongs to the B&R X20 automation system. Specify X20CP1485 by its complete designation and documented role; the visible similarity of two modules is not a compatibility decision.
Identification matrix
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | X20CP1485 |
| Processor | Intel Celeron 400 Performance |
| Onboard | Ethernet, POWERLINK and USB |
| Expansion | One modular interface slot |
The values above identify X20CP1485 at catalog level. Verify the installed revision, label and current manufacturer manual before issuing a purchase order or approving a design change.
01 / Intended duty
For X20CP1485, Use this controller where the approved X20 application needs the specified CPU and a single communication expansion slot.
Capture the actual cabinet location, connected equipment, expected operating range and the consequence of a lost signal or network connection. These details turn the X20CP1485 code into a specific engineering requirement.
03 / Acceptance record
For commissioning X20CP1485, Restore the validated project and test network exchange, I/O scan, alarms and controlled machine starts.
Record date, test conditions, observed LEDs or diagnostics and as-left configuration for X20CP1485. Restore normal control after testing and obtain the site's electrical or safety sign-off where required.
02 / Fit boundary
When replacing or adding X20CP1485, Back up CompactFlash and compare the installed interface module, firmware and application memory; the -1 code is a distinct revision reference.
Check X20CP1485 against the as-built wiring, X20 base, terminal block, supply module and controller software. Keep every accessory and revision difference visible in the RFQ; do not approve a look-alike solely from a photograph.
Code alternatives and exclusions
The references below, if any, share a relevant X20CP1485 code stem or functional family. Their ratings, ports, wiring or software may differ; they are not automatic replacements.
- X20CP1485-1
Purchase handover
Quote X20CP1485 exactly, with quantity, required delivery, existing hardware revision and a readable label photograph. Attach the application drawing and network or channel map so the supplier can confirm the right product and accessories.
The buyer should retain a written fit decision for X20CP1485, and maintenance should keep the final settings and test evidence. Do not energize a replacement until the approved checks are complete.