ABB XT1C 160 TMD 125-1250 3P F F | 125 A Thermal-Magnetic Trip and Three-Pole Fixed Mounting

description:Technical identification and selection guidance for ABB XT1C 160 TMD 125-1250 3P F F, including verified family data, system compatibility and configuration checks....
BASIC INFO

XT1C 160 TMD 125-1250 3P F F: XT1C 160 TMD breaker selection for feeder protection and panel coordination

XT1C 160 TMD 125-1250 3P F F is an ABB Tmax XT1 molded-case circuit-breaker configuration with a TMD thermal-magnetic trip unit. This designation maps to ABB order code 1SDA067398R1. Check the complete label for the exact nominal current, magnetic trip threshold, breaking capacity and fixed/front-connection arrangement before using XT1C 160 TMD 125-1250 3P F F in a replacement specification.

Key technical data

Technical itemVerified value / selection note
ModelXT1C 160 TMD 125-1250 3P F F
ABB order code1SDA067398R1
Frame familyTmax XT1C 160
Trip unitTMD thermal-magnetic
Current designation125 A thermal setting class with magnetic threshold indicated by 125-1250 A code; verify exact trip data
Poles / mounting3-pole, fixed, front connection designation
Breaking capacityCheck the exact voltage-specific Icu/Ics rating on ABB documentation

Identification note: XT1C 160 TMD 125-1250 3P F F. The figures above are selection references; verify the actual label, duty rating, approvals, firmware and options for the exact unit before purchase or engineering release.

Application envelope

This XT1C 160 variant can be evaluated for three-pole feeder or equipment protection where its voltage and fault interruption capability match the installation. Protection studies should account for conductor ampacity, motor or transformer inrush, downstream selectivity and the upstream device. A frame-size match alone is not an electrical equivalence check.

  1. Confirm the process or load duty.
  2. Match the exact code and interfaces.
  3. Verify protection, approvals and lifecycle status.

Model family references

The following model references belong to the same identifiable family as XT1C 160 TMD 125-1250 3P F F; they are configuration alternatives, not automatic substitutes. Compare each complete designation and application before selecting.

  • 1SDA067398R1, XT1C 160 TMD 125-1250 3P F F

For the XT1C 160 TMD 125-1250 3P F F record, retain the full type string and do not infer range, rating or compatibility from a shortened family code.

Order-code review

For XT1C 160 TMD 125-1250 3P F F, verify rated operational voltage, Icu/Ics, thermal setting, instantaneous threshold, terminal kit, mounting style and any required auxiliary or trip accessories. Confirm the switchboard's busbar and clearance arrangements. Match the exact suffix and ABB order number rather than selecting from a shortened XT1C label.

Commissioning record

Isolate the switchboard, rack or mount the breaker only as designed, and observe the manufacturer's handling and torque instructions. Check trip-unit settings, terminal connections, interlocks and accessory wiring. Complete the approved injection or functional test and retain the exact breaker configuration and coordination record.

For procurement, quote the complete designation XT1C 160 TMD 125-1250 3P F F and state the required quantity, destination, duty and delivery window.

 

 