What the complete 50FY41-V4A-6-KIT code means for this installation

Pepperl+Fuchs 50FY41-V4A-6-KIT is a Hall-effect magnetic sensor kit used to detect a matched magnet in a machine. This service brief separates the confirmed identity of 50FY41-V4A-6-KIT from the installation choices that must be checked on site. The shared Pepperl+Fuchs main image is an illustrative category montage, not an exact photograph of 50FY41-V4A-6-KIT. Use the complete designation on the fitted label when enquiring or replacing the part.

Technical parameters at a glance

Technical itemVerified value / selection note
Exact model50FY41-V4A-6-KIT
Product roleHall-effect magnetic sensor kit
KitSensor and magnet
Rated distance2.5 mm at zero offset
Output4-wire PNP/NPN, normally open
Supply10 to 12 V DC
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Replacement file

Before ordering 50FY41-V4A-6-KIT, photograph the nameplate and document what is connected on each side of the device. Check supply, signal or mechanical interface, mounting, environmental exposure and the receiving controller. The table is a compact technical reference for 50FY41-V4A-6-KIT; a similar printed string can denote another function, rating or certification. Retain any parameter backup and the current drawing with the maintenance record.

Functional path

In operation, 50FY41-V4A-6-KIT is intended to detect a matched magnet in a machine. Establish the real input condition, the expected output response and the acceptance limit. Where an accessory, receiver, host card, reflector or magnet is required, include that matched part in the bill of materials. Do not infer that the picture or a neighbouring model code establishes compatibility for 50FY41-V4A-6-KIT.

Wiring and fit gate

At installation, Prove target offset and wiring against the actual magnet supplied in the kit. Confirm power is isolated where required and compare the connector or terminals against the current manufacturer documentation for 50FY41-V4A-6-KIT. Verify safe-area and hazardous-area boundaries where applicable; the exact certificate and site wiring govern the final decision. Leave enough clearance for the fitted cable and normal service access.

Proof of operation

Commission 50FY41-V4A-6-KIT with an observable, known condition rather than only checking an indicator lamp. Record at least two input states and their controller responses, then test the edge of the real working range where practical. If 50FY41-V4A-6-KIT is part of a safety or Ex installation, use the site's approved proof-test procedure and exact approval documents. Save settings, photos and measured results so a later replacement can be compared reliably.

Buying note

A useful quotation request for 50FY41-V4A-6-KIT includes the full code, quantity, site function, connection type, any mating accessory and required approval. Ask the supplier to confirm every changed suffix on a proposed alternative. This page does not declare that other visually similar codes are interchangeable with 50FY41-V4A-6-KIT; each requires its own data and fit review.

Visually related codes

The following model strings resemble 50FY41-V4A-6-KIT in print. They are collected for search and stock recognition only; electrical and mechanical functions can differ. Verify every complete designation independently.

No additional same-pattern designation is grouped with 50FY41-V4A-6-KIT in this selection.

Handover note

Keep the final 50FY41-V4A-6-KIT nameplate photo, fit check and test record with the machine file. Re-check the exact model whenever the host, process or installation environment changes.

 

 