Pepperl+Fuchs HiATB01-HART-2X16 is a HART communication board used to collect HART signals from an H-System termination board. This entry identifies the complete HiATB01-HART-2X16 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of HiATB01-HART-2X16. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.

Key technical data

Technical itemVerified value / selection note
Exact modelHiATB01-HART-2X16
Product roleHART communication board
Channel grouping2 x 16
Supply24 V DC
Network2 RS-485 connections
SystemCompatible HiC termination boards
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Installation record

For a replacement HiATB01-HART-2X16, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for HiATB01-HART-2X16; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.

Process role

The job of HiATB01-HART-2X16 is to collect HART signals from an H-System termination board. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like HiATB01-HART-2X16 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.

Test record

At commissioning, Check both 16-channel groups, RS-485 network and HiDMux module. Test HiATB01-HART-2X16 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that HiATB01-HART-2X16 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.

Order record

An RFQ for HiATB01-HART-2X16 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named HiATB01-HART-2X16 variant where verified. Each other complete code needs its own specification review.

Related-looking model strings

These designations visually resemble HiATB01-HART-2X16; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.

  • HiATB01-FAULT-01
  • HiATB01-HART-4X8
  • HIATB01-HART-4x8-Y1

Close-out

After the handover of HiATB01-HART-2X16, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for HiATB01-HART-2X16. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.

Further Pepperl+Fuchs look-alike model references

These are additional printed model strings grouped for product search only. A similar-looking code can describe another device, connection, rating or certification. It is not automatically a substitute for HiATB01-HART-2X16. Check the full manufacturer designation and the installed system independently.

  • HITB16X-TRI-AIISS-EL-PL

 

 

Pre:Pepperl+Fuchs EI-0D2-10Y-10B Technical Product Record | Intrinsically Safe Ethernet Isolator and System Checks Next:KT-MB-GT2AD.FF Pepperl+Fuchs Fieldbus Diagnostic Gateway Kit | Connections, Commissioning and Order Code