From nameplate to commissioning: M100/MV100-RT/35/76a/95/103

Pepperl+Fuchs M100/MV100-RT/35/76a/95/103 is a thru-beam photoelectric sensor pair used to detect objects between an emitter and a receiver. This entry identifies the complete M100/MV100-RT/35/76a/95/103 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of M100/MV100-RT/35/76a/95/103. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.

Key technical data

Technical itemVerified value / selection note
Exact modelM100/MV100-RT/35/76a/95/103
Product rolethru-beam photoelectric sensor pair
PairM100 emitter and MV100 receiver
Effective rangeUp to 20 m for this pair
LightVisible red
ConnectionM8 4-pin plug
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

System boundary

The job of M100/MV100-RT/35/76a/95/103 is to detect objects between an emitter and a receiver. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like M100/MV100-RT/35/76a/95/103 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.

Replacement gate

For a replacement M100/MV100-RT/35/76a/95/103, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for M100/MV100-RT/35/76a/95/103; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.

Record the complete M100/MV100-RT/35/76a/95/103 code before comparing any similar-looking part.

Acceptance evidence

At commissioning, Align the optical pair and prove the PNP receiver state at the controller. Test M100/MV100-RT/35/76a/95/103 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that M100/MV100-RT/35/76a/95/103 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.

Purchasing handoff

An RFQ for M100/MV100-RT/35/76a/95/103 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named M100/MV100-RT/35/76a/95/103 variant where verified. Each other complete code needs its own specification review.

Related-looking model strings

These designations visually resemble M100/MV100-RT/35/76a/95/103; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.

  • M100/MV100-RT/35/76a/95/103 (214743)
  • M100/MV100-RT/76a/95/103

Close-out

After the handover of M100/MV100-RT/35/76a/95/103, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for M100/MV100-RT/35/76a/95/103. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.

 

 