A buyer's technical review of Pepperl+Fuchs NJ0,8-5GM-N

Pepperl+Fuchs NJ0,8-5GM-N is a NAMUR inductive proximity sensor for monitoring a metal target at a very short sensing gap. The shared product montage is a category reference image rather than a photo of this exact NJ0,8-5GM-N variant. The table places the verified identity and useful selection data at the front; the notes below explain where a maintenance or purchasing team should confirm the installed circuit.

Technical parameters and fit

Technical itemVerified value / selection note
Exact modelNJ0,8-5GM-N
Product roleNAMUR inductive proximity sensor
Rated distance0.8 mm
Switching functionNormally closed NAMUR, 2-wire
MountingFlush, M5 cylindrical body
Nominal supply8.2 V NAMUR circuit
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Application path

In this installation, NJ0,8-5GM-N supports monitoring a metal target at a very short sensing gap. Start at the field device or mechanical target, follow the signal through the connection and identify what the host expects. A catalog family resemblance cannot establish output polarity, scaling, hazardous-area approval or interchangeability. The complete NJ0,8-5GM-N code is the procurement reference, while the as-installed drawing is the acceptance reference.

Installation interface

Before fitting NJ0,8-5GM-N, Match the NAMUR amplifier and the M5 mounting arrangement; a conventional DC transistor input is not the same interface. Inspect available cabinet or machine space, cable exit, terminals, environmental limits and nearby equipment. If an old unit has user settings, document them before removal. Confirm the latest nameplate and electrical drawing because NJ0,8-5GM-N variants can share an enclosure while differing in function.

On-site proof

After NJ0,8-5GM-N is connected, Check the low/high current interpretation with the installed switch amplifier and prove the actual target gap. Record the input condition and the controller's observed response at both ends of the useful operating range. Also check supply, diagnostics and any line-fault indication. A successful power-on indication alone does not prove that NJ0,8-5GM-N has the correct configuration.

Replacement decision

When purchasing NJ0,8-5GM-N, Retain the comma in the 0,8 designation and confirm cable length and hazardous-area documents. Share the full model, site photos and required certificates with the supplier. Any proposed alternative should be checked against the exact connected equipment and signed off before it replaces NJ0,8-5GM-N; a similar-looking code is a search reference, not a declared equivalent.

Other visually related ordering codes

The following designations resemble the NJ0,8-5GM-N naming pattern and are collected here to help buyers locate variants. Their functions, electrical ratings, connections and approvals may differ. The exact NJ0,8-5GM-N technical values above must not be copied onto another suffix without checking its own datasheet.

  • NJ 40+U4+E 15833
  • NJ-18GK-N-150
  • NJ1,5-18GM-N-D
  • NJ1,5-18GM-N-D-10M
  • NJ1,5-18GM-N-D-V1
  • NJ1,5-6,5-N
  • NJ1,5-8-N-Y18812
  • NJ1,5-8GM-N
  • NJ1,5-8GM-N-V1
  • NJ10-30GK-N
  • NJ10-30GK-N-15M
  • NJ10-30GK-SN
  • NJ10-30GK-SN, P/N 106667
  • NJ10-30GK-SN-10M
  • NJ10-30GK-SN-15M
  • NJ10-30GM-N
  • NJ10-30GM-N-5M
  • NJ10-30GM-N-V1
  • NJ10-30GM50-A2-V1
  • NJ10-30GM50-E
  • NJ10-30GM50-E2-V1-3G-3D
  • NJ15+U1+2E2-NE/FE
  • NJ15+U1+DW2-1
  • NJ15+U1+N
  • NJ15+U4+N
  • NJ15-30GK-N
  • NJ15-30GK-N, 70133317
  • NJ15-30GK-N-10M
  • NJ15-30GK-N-150
  • NJ15-30GK-SN-5M
  • NJ15-30GK50-E
  • NJ15-30GKK-N
  • NJ15-30GM-N
  • NJ15-M1-E2-V1
  • NJ15-M1-E2V1 Y29034
  • NJ15-M1K-N
  • NJ15S+U1+N
  • NJ18-18GK-N-150
  • NJ2,5-14GM-N-V1-Y21146
  • NJ2-11-N-G
  • NJ2-11-N-G 123G1xxD
  • NJ2-11-N-G7829
  • NJ2-11-SN-G
  • NJ2-12GK-N
  • NJ2-12GK-SN
  • NJ2-12GM-N
  • NJ2-12GM-N-10M
  • NJ2-12GM40-E2
  • NJ2-PD-E02-4.562-V95
  • NJ2-PD-US-2.875-V93
  • NJ2-PD-US-4.562-V93
  • NJ2-V3-N
  • NJ2-V3-N-0,075M ( PN:250497)
  • NJ2-V3-N-0075M
  • NJ2-V3-N-Y211641
  • NJ2-V3-N-Y220141
  • NJ20+U1+E2
  • NJ20S+U1+N
  • NJ3-18GK-S1N
  • NJ3-18GK-S1N-10M
  • NJ4-12-GK-SN
  • NJ4-12GK-N
  • NJ4-12GK-N-5M
  • NJ4-12GK-N-C92
  • NJ4-12GK-SN-15M
  • NJ4-12GM-N-10M
  • NJ4-12GM-N-5M-Y12325
  • NJ4-12GM40-E2-5M
  • NJ4-12GM40-E2-V1
  • NJ4-12GM50-WS-10M
  • NJ4-30GM-N-200
  • NJ40+U1+A2-T
  • NJ40+U1+N
  • NJ40+U10+E2
  • NJ40+U10+E2-Y111580
  • NJ40+U4+N
  • NJ40-FP-SN-P1
  • NJ5-11-N-G
  • NJ5-11-N-G-5M
  • NJ5-11-N-G-6M
  • NJ5-11-N-G-Y112726
  • NJ5-18 GK-SN
  • NJ5-18GK-N
  • NJ5-18GK-N-150
  • NJ5-18GK-N-5M
  • NJ5-18GK-SN-10M
  • NJ5-18GM-N
  • NJ5-18GM-N-V1
  • NJ5-18GM50-A2-V1
  • NJ5-18GM50-E2-V1
  • NJ5-18GM50-E2-V1(#282958)
  • NJ5-30GK-S1N
  • NJ50-FP-E-P1
  • NJ6-22-N-G
  • NJ6-22-SN-G
  • NJ6-F-A2
  • NJ60-FP-A2-P1-Y237069
  • NJ6S1+U1+N1
  • NJ8- 18GM50-E2- V1
  • NJ8-18GK-N
  • NJ8-18GK-N-150
  • NJ8-18GK-SN
  • NJ8-18GM-N
  • NJ8-18GM-N-5M
  • NJ8-18GM-N-V1
  • NJ8-18GM50-A2-V1
  • NJ8-18GM50-E2
  • NJ8-18GM50-E2-10M

Handover note

Keep the drawing, configured settings, inspection result and purchasing record with NJ0,8-5GM-N. Recheck the current manufacturer datasheet if the duty, mounting, network or approval changes. This closes the NJ0,8-5GM-N selection and commissioning review without treating related codes as interchangeable.

 

 

Pre:Pepperl+Fuchs 3003-LPS-CI-YZ-VPM Product Details | Enclosure Purge And Pressurization System, System Compatibility and Commissioning Next:SJ10-E2 Pepperl+Fuchs Inductive Slot Sensor: Interface Matching and Maintenance Guide