From nameplate to commissioning: VDM28-50-R1-IO/73C/110/122

Pepperl+Fuchs VDM28-50-R1-IO/73C/110/122 is a laser distance sensor used to measure reflector distance over an industrial travel path. This entry identifies the complete VDM28-50-R1-IO/73C/110/122 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of VDM28-50-R1-IO/73C/110/122. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.

Key technical data

Technical itemVerified value / selection note
Exact modelVDM28-50-R1-IO/73C/110/122
Product rolelaser distance sensor
Measuring range0.2 to 50 m
MethodPulse Ranging Technology
LightVisible red laser
InterfaceIO-Link variant
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Decision memo

The job of VDM28-50-R1-IO/73C/110/122 is to measure reflector distance over an industrial travel path. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like VDM28-50-R1-IO/73C/110/122 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.

Match the installed assembly

For a replacement VDM28-50-R1-IO/73C/110/122, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for VDM28-50-R1-IO/73C/110/122; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.

Prove the function

At commissioning, Prove reference target, IO-Link data and output scaling at two distances. Test VDM28-50-R1-IO/73C/110/122 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that VDM28-50-R1-IO/73C/110/122 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.

Send a complete enquiry

An RFQ for VDM28-50-R1-IO/73C/110/122 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named VDM28-50-R1-IO/73C/110/122 variant where verified. Each other complete code needs its own specification review.

Related-looking model strings

These designations visually resemble VDM28-50-R1-IO/73C/110/122; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.

No additional same-pattern code is grouped with VDM28-50-R1-IO/73C/110/122 here; any alternative requires its own review.

Close-out

After the handover of VDM28-50-R1-IO/73C/110/122, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for VDM28-50-R1-IO/73C/110/122. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.

 

 

Pre:REF-H50 Pepperl+Fuchs Photoelectric Reflector | Connections, Commissioning and Order Code Next:Buying Pepperl+Fuchs RC10-14-N3 Inductive Ring Sensor for an Existing Installation