BASIC INFO
Product overview
ATS22D32Q original schneider soft starter 7.5-15kw
ATS22D32Q product specification as below
Other related models for Schneider Altistart 22 series soft starter for your reference.
ATS22C21Q
ATS22C25Q
ATS22C48Q
ATS22D62Q
ATS22C17Q
ATS22D17Q
ATS22D32Q
ATS22D88Q
ATS22C14Q
ATS22C32Q
ATS22C41Q
ATS22C59Q
ATS22D47Q
ATS22D75Q
ATS22C11Q
If you need more details for Schneider Altistart 22 ATS22D32Q, please contact me online or send me an inquiry.
contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com
Website:http://www.hkxy-lowvoltage.com/
ATS22D32Q original schneider soft starter 7.5-15kw
ATS22D32Q product specification as below
Characteristics
Main
Complementary
Environment
Offer Sustainability
range of product |
Altistart 22
|
|
product or component type |
Soft starter
|
|
product destination |
Asynchronous motors
|
|
product specific application |
Pumps and fans
|
|
component name |
ATS22
|
|
network number of phases |
3 phases
|
|
[Us] rated supply voltage |
230...440 V - 15...10 %
|
|
motor power kW |
15 kW 400 V
7.5 kW 230 V 15 kW 440 V |
|
factory setting current |
28.5 A
|
|
power dissipation in W |
44 W for standard applications
|
|
utilisation category |
AC-53A
|
|
type of start |
Start with torque control (current limited to 3.5 In)
|
|
IcL starter rating |
32 A connection in the motor supply line for standard applications
|
|
IP degree of protection |
IP20
|
assembly style |
With heat sink
|
|
function available |
Internal bypass
|
|
supply voltage limits |
195...484 V
|
|
supply frequency |
50...60 Hz - 10...10 %
|
|
network frequency |
45...66 Hz
|
|
device connection |
In the motor supply line
To the motor delta terminals |
|
[Uc] control circuit voltage |
230 V -15...10 % 50/60 Hz
|
|
control circuit consumption |
20 W
|
|
discrete output number |
2
|
|
discrete output type |
Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O
Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
|
minimum switching current |
100 mA 12 V DC relay outputs
|
|
maximum switching current |
5 A 250 V AC resistive 1 relay outputs
5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs |
|
discrete input number |
3
|
|
discrete input type |
Logic LI1, LI2, LI3 5 mA 4.3 kOhm
|
|
discrete input voltage |
24 V <= 30 V
|
|
discrete input logic |
Positive logic LI1, LI2, LI3 < 5 V and <= 2 mA > 11 V >= 5 mA
|
|
output current |
0.4...1 Icl adjustable
|
|
PTC probe input |
750 Ohm
|
|
communication port protocol |
Modbus
|
|
connector type |
1 RJ45
|
|
communication data link |
Serial
|
|
physical interface |
RS485 multidrop
|
|
transmission rate |
4800, 9600 or 19200 bps
|
|
installed device |
31
|
|
protection type |
Phase failure line
Thermal protection starter Thermal protection motor |
|
marking |
CE
|
|
type of cooling |
Forced convection
|
|
operating position |
Vertical +/- 10 degree
|
|
height |
265 mm
|
|
width |
130 mm
|
|
depth |
169 mm
|
|
product weight |
7 kg
|
|
power range |
7...11 kW at 200...240 V 3 phases
15...25 kW at 380...440 V 3 phases |
|
motor starter type |
Soft starter
|
electromagnetic compatibility |
Conducted and radiated emissions level A IEC 60947-4-2
Damped oscillating waves level 3 IEC 61000-4-12 Electrostatic discharge level 3 IEC 61000-4-2 Immunity to electrical transients level 4 IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 IEC 61000-4-3 Voltage/current impulse level 3 IEC 61000-4-5 |
|
standards |
EN/IEC 60947-4-2
|
|
product certifications |
CSA
GOST CCC UL C-Tick |
|
vibration resistance |
1.5 mm 2...13 Hz EN/IEC 60068-2-6
1 gn 13...200 Hz EN/IEC 60068-2-6 |
|
shock resistance |
15 gn 11 ms EN/IEC 60068-2-27
|
|
noise level |
45 dB
|
|
pollution degree |
Level 2 IEC 60664-1
|
|
relative humidity |
0...95 % without condensation or dripping water EN/IEC 60068-2-3
|
|
ambient air temperature for operation |
-10...40 °C without derating
> 40...< 60 °C with current derating 2.2 % per °C |
|
ambient air temperature for storage |
-25...70 °C
|
|
operating altitude |
<= 1000 m without derating
> 1000...< 2000 m with current derating of 2.2 % per additional 100 m |
Sustainable offer status |
Green Premium product
|
|
RoHS (date code: YYWW) |
Compliant - since 0938 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity
|
|
REACh | ||
Product environmental profile |
AvailableProduct environmental
|
|
Product end of life instructions |
AvailableEnd of life manual
|
Other related models for Schneider Altistart 22 series soft starter for your reference.
ATS22C21Q
ATS22C25Q
ATS22C48Q
ATS22D62Q
ATS22C17Q
ATS22D17Q
ATS22D32Q
ATS22D88Q
ATS22C14Q
ATS22C32Q
ATS22C41Q
ATS22C59Q
ATS22D47Q
ATS22D75Q
ATS22C11Q
If you need more details for Schneider Altistart 22 ATS22D32Q, please contact me online or send me an inquiry.
contact details
HONGKONG XIEYUAN TECH CO., LIMITED
Telephone:86-027-85880977
Mobile :86-13545206420(Whatapp&Wechat is available)
Fax:86-027-85309780
Skype:Diana@hkxytech.com
E-mail:Diana@hkxytech.com
Website:http://www.hkxy-lowvoltage.com/