BASIC INFO
Product overview
100% Original Siemens 3VA6 molded case circuit breakers
3VA6 molded case circuit breakers
The new 3VA6 molded case circuit breakers reliably perform all the tasks required for circuit protection and protection of starter combinations.
This series is designed for applications with increased requirements:
• Increased breaking capacity
• Integrated metering function
• Connection to a communication system
Features
The most important features of the 3VA6 series are:
• Compact dimensions
• 3 and 4-pole versions
• Four breaking capacity classes of 35 kA … 150 kA at 480 V and 18 kA … 50 kA at 600 V
• Fixed-mounting, plug-in technology, draw-out technology
• Electronic Trip Units
• Retrofittable communication for ETU 5-series and 8-series • Depending on the ETU: Integrated metering function
• AC applications
• No derating up to +50 °C
• Modular and easy-to-fit internal accessories with diverse functions
• Uniform accessories platform across all 3VA5/3VA6 molded case circuit breakers
Compact dimensions with function expansions
In addition to its expanded functionality, the 3VA6 molded case circuit breaker also comes with compact dimensions for fixed mounting, as a plug-in version and a draw-out version.
A cover size of 70 mm (up to 600 A) for the door cutout and a complete selection of breaking capacity classes from 35 kA to 150 kA at 480 V provide the necessary flexibility for planning. Despite its compact size, the circuit breaker offers the following benefits:
• Very high short-circuit breaking capacity
• Electronic trip units, versions with and without integrated metering function and optional communication interface
Electronic Trip Units (ETUs)
The current sensors of the 3VA6 comprise iron-cored transformers for the internal power supply and Rogowski coils for precise current measurement. Each transformer can be optimized accordingly for its specific task. Thanks to the high accuracy of current measurement, the 3VA6 molded case circuit breaker is suitable for power/energy measurement. In addition, finer adjustment of ground fault current monitoring is possible.
The Electronic Trip Units (ETUs) provide the following protection functions:
• Overload protection L ("L" = Long-time delay)
• Short-time delayed short-circuit protection S ("S" = Short-time delay) for time-selective response in case of a short-circuit
• Instantaneous short-circuit protection I ("I" = Instantaneous)
• Protection of the neutral conductor N against overload and short-circuit ("N" = Neutral)
• Protection against residual currents to ground ("G" = Ground fault)
• Ground fault detection (G alarm = ground fault alarm) does not trip the circuit breaker, but an indication is shown on the display and/or is communicated to higher-level systems via the communication path or EFB/MMB.
Energy management and communication The Electronic Trip Units (ETUs) provide the following energy management and communication functions:
• Metering function for current, voltage, power rating and energy
• Transfer of measured value data and breaker status information
• Remote parameter assignment of tripping thresholds and miscellaneous parameters
• Flexible use of digital inputs and outputs of the optionally available EFB300 external function box
• Commissioning/setting the plant topology and also individual breaker parameters with the "powerconfig" software package
• Testing and archiving with the TD300 and TD500 test devices (with powerconfig)
ETU556 LSI(G) with display
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd,
adjustable instantaneous short-circuit protection Ii and adjustable ground-fault alarm Ig
3VA6140-6JT41-0AA0
3VA6140-7JT41-0AA0
3VA6140-8JT41-0AA0
3VA6110-6JT41-0AA0
3VA6110-7JT41-0AA0
3VA6110-8JT41-0AA0
3VA6115-6JT41-0AA0
3VA6115-7JT41-0AA0
3VA6115-8JT41-0AA0
3VA6210-6JT41-0AA0
3VA6210-7JT41-0AA0
3VA6210-8JT41-0AA0
3VA6225-6JT41-0AA0
3VA6225-7JT41-0AA0
3VA6225-8JT41-0AA0
3VA6325-6JT41-0AA0
3VA6325-7JT41-0AA0
3VA6325-8JT41-0AA0
3VA6340-6JT41-0AA0
3VA6340-7JT41-0AA0
3VA6340-8JT41-0AA0
3VA6440-6JT41-0AA0
3VA6440-7JT41-0AA0
3VA6440-8JT41-0AA0
3VA6460-6JT41-0AA0
3VA6460-7JT41-0AA0
3VA6460-8JT41-0AA0
ETU560 LSIG with display
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
and adjustable ground-fault protection Ig
3VA6140-6JQ41-0AA0
3VA6140-7JQ41-0AA0
3VA6140-8JQ41-0AA0
3VA6110-6JQ41-0AA0
3VA6110-7JQ41-0AA0
3VA6110-8JQ41-0AA0
3VA6115-6JQ41-0AA0
3VA6115-7JQ41-0AA0
3VA6115-8JQ41-0AA0
3VA6210-6JQ41-0AA0
3VA6210-7JQ41-0AA0
3VA6210-8JQ41-0AA0
3VA6225-6JQ41-0AA0
3VA6225-7JQ41-0AA0
3VA6225-8JQ41-0AA0
3VA6325-6JQ41-0AA0
3VA6325-7JQ41-0AA0
3VA6325-8JQ41-0AA0
3VA6340-6JQ41-0AA0
3VA6340-7JQ41-0AA0
3VA6340-8JQ41-0AA0
3VA6440-6JQ41-0AA0
3VA6440-7JQ41-0AA0
3VA6440-8JQ41-0AA0
3VA6460-6JQ41-0AA0
3VA6460-7JQ41-0AA0
3VA6460-8JQ41-0AA0
4-pole, fixed-mounted, 3VA61 to 3VA64, up to 600 A
Electronic Trip Unit
ETU820 LI with display and metering function
With adjustable overload protection Ir and adjustable instantaneous short-circuit protection Ii
3VA6140-5KL41-0AA0
3VA6110-5KL41-0AA0
3VA6115-5KL41-0AA0
3VA6210-5KL41-0AA0
3VA6225-5KL41-0AA0
3VA6325-5KL41-0AA0
3VA6340-5KL41-0AA0
3VA6440-5KL41-0AA0
3VA6460-5KL41-0AA0
ETU830 LIG with display and metering function
With adjustable overload protection Ir, adjustable instantaneous short-circuit protection Ii
and adjustable ground-fault protection Ig
3VA6140-5KM41-0AA0
3VA6110-5KM41-0AA0
3VA6115-5KM41-0AA0
3VA6210-5KM41-0AA0
3VA6225-5KM41-0AA0
3VA6325-5KM41-0AA0
3VA6340-5KM41-0AA0
3VA6440-5KM41-0AA0
3VA6460-5KM41-0AA0
ETU820 LI with display and metering function
With adjustable overload protection Ir and adjustable instantaneous short-circuit protection Ii
3VA6140-6KL41-0AA0
3VA6140-7KL41-0AA0
3VA6140-8KL41-0AA0
3VA6110-6KL41-0AA0
3VA6110-7KL41-0AA0
3VA6110-8KL41-0AA0
3VA6115-6KL41-0AA0
3VA6115-7KL41-0AA0
3VA6115-8KL41-0AA0
3VA6210-6KL41-0AA0
3VA6210-7KL41-0AA0
3VA6210-8KL41-0AA0
3VA6225-6KL41-0AA0
3VA6225-7KL41-0AA0
3VA6225-8KL41-0AA0
3VA6325-6KL41-0AA0
3VA6325-7KL41-0AA0
3VA6325-8KL41-0AA0
3VA6340-6KL41-0AA0
3VA6340-7KL41-0AA0
3VA6340-8KL41-0AA0
3VA6440-6KL41-0AA0
3VA6440-7KL41-0AA0
3VA6440-8KL41-0AA0
3VA6460-6KL41-0AA0
3VA6460-7KL41-0AA0
3VA6460-8KL41-0AA0
ETU830 LIG with display and metering function
With adjustable overload protection Ir, adjustable instantaneous short-circuit protection Ii
and adjustable ground-fault protection Ig
3VA6140-6KM41-0AA0
3VA6140-7KM41-0AA0
3VA6140-8KM41-0AA0
3VA6110-6KM41-0AA0
3VA6110-7KM41-0AA0
3VA6110-8KM41-0AA0
3VA6115-6KM41-0AA0
3VA6115-7KM41-0AA0
3VA6115-8KM41-0AA0
3VA6210-6KM41-0AA0
3VA6210-7KM41-0AA0
3VA6210-8KM41-0AA0
3VA6225-6KM41-0AA0
3VA6225-7KM41-0AA0
3VA6225-8KM41-0AA0
3VA6325-6KM41-0AA0
3VA6325-7KM41-0AA0
3VA6325-8KM41-0AA0
3VA6340-6KM41-0AA0
3VA6340-7KM41-0AA0
3VA6340-8KM41-0AA0
3VA6440-6KM41-0AA0
3VA6440-7KM41-0AA0
3VA6440-8KM41-0AA0
3VA6460-6KM41-0AA0
3VA6460-7KM41-0AA0
3VA6460-8KM41-0AA0
4-pole, fixed-mounted, 3VA61 to 3VA64, up to 600 A
Electronic Trip Unit
ETU850 LSI with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-5KP41-0AA0
3VA6110-5KP41-0AA0
3VA6115-5KP41-0AA0
3VA6210-5KP41-0AA0
3VA6225-5KP41-0AA0
3VA6325-5KP41-0AA0
3VA6340-5KP41-0AA0
3VA6440-5KP41-0AA0
3VA6460-5KP41-0AA0
ETU856 LSI(G) with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd,
adjustable instantaneous short-circuit protection Ii and adjustable ground-fault alarm Ig,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-5KT41-0AA0
3VA6110-5KT41-0AA0
3VA6115-5KT41-0AA0
3VA6210-5KT41-0AA0
3VA6225-5KT41-0AA0
3VA6325-5KT41-0AA0
3VA6340-5KT41-0AA0
3VA6440-5KT41-0AA0
3VA6460-5KT41-0AA0
ETU860 LSIG with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
and adjustable ground-fault protection Ig
3VA6140-5KQ41-0AA0
3VA6110-5KQ41-0AA0
3VA6115-5KQ41-0AA0
3VA6210-5KQ41-0AA0
3VA6225-5KQ41-0AA0
3VA6325-5KQ41-0AA0
3VA6340-5KQ41-0AA0
3VA6440-5KQ41-0AA0
3VA6460-5KQ41-0AA0
ETU850 LSI with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-6KP41-0AA0
3VA6140-7KP41-0AA0
3VA6140-8KP41-0AA0
3VA6110-6KP41-0AA0
3VA6110-7KP41-0AA0
3VA6110-8KP41-0AA0
3VA6115-6KP41-0AA0
3VA6115-7KP41-0AA0
3VA6115-8KP41-0AA0
3VA6210-6KP41-0AA0
3VA6210-7KP41-0AA0
3VA6210-8KP41-0AA0
3VA6225-6KP41-0AA0
3VA6225-7KP41-0AA0
3VA6225-8KP41-0AA0
3VA6325-6KP41-0AA0
3VA6325-7KP41-0AA0
3VA6325-8KP41-0AA0
3VA6340-6KP41-0AA0
3VA6340-7KP41-0AA0
3VA6340-8KP41-0AA0
3VA6440-6KP41-0AA0
3VA6440-7KP41-0AA0
3VA6440-8KP41-0AA0
3VA6460-6KP41-0AA0
3VA6460-7KP41-0AA0
3VA6460-8KP41-0AA0
ETU856 LSI(G) with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd,
adjustable instantaneous short-circuit protection Ii and adjustable ground-fault alarm Ig,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-6KT41-0AA0
3VA6140-7KT41-0AA0
3VA6140-8KT41-0AA0
3VA6110-6KT41-0AA0
3VA6110-7KT41-0AA0
3VA6110-8KT41-0AA0
3VA6115-6KT41-0AA0
3VA6115-7KT41-0AA0
3VA6115-8KT41-0AA0
3VA6210-6KT41-0AA0
3VA6210-7KT41-0AA0
3VA6210-8KT41-0AA0
3VA6225-6KT41-0AA0
3VA6225-7KT41-0AA0
3VA6225-8KT41-0AA0
3VA6325-6KT41-0AA0
3VA6325-7KT41-0AA0
3VA6325-8KT41-0AA0
3VA6340-6KT41-0AA0
3VA6340-7KT41-0AA0
3VA6340-8KT41-0AA0
3VA6440-6KT41-0AA0
3VA6440-7KT41-0AA0
3VA6440-8KT41-0AA0
3VA6460-6KT41-0AA0
3VA6460-7KT41-0AA0
3VA6460-8KT41-0AA0
100% Original Siemens 3VA6 molded case circuit breakers
3VA6 molded case circuit breakers
The new 3VA6 molded case circuit breakers reliably perform all the tasks required for circuit protection and protection of starter combinations.
This series is designed for applications with increased requirements:
• Increased breaking capacity
• Integrated metering function
• Connection to a communication system
Features
The most important features of the 3VA6 series are:
• Compact dimensions
• 3 and 4-pole versions
• Four breaking capacity classes of 35 kA … 150 kA at 480 V and 18 kA … 50 kA at 600 V
• Fixed-mounting, plug-in technology, draw-out technology
• Electronic Trip Units
• Retrofittable communication for ETU 5-series and 8-series • Depending on the ETU: Integrated metering function
• AC applications
• No derating up to +50 °C
• Modular and easy-to-fit internal accessories with diverse functions
• Uniform accessories platform across all 3VA5/3VA6 molded case circuit breakers
Compact dimensions with function expansions
In addition to its expanded functionality, the 3VA6 molded case circuit breaker also comes with compact dimensions for fixed mounting, as a plug-in version and a draw-out version.
A cover size of 70 mm (up to 600 A) for the door cutout and a complete selection of breaking capacity classes from 35 kA to 150 kA at 480 V provide the necessary flexibility for planning. Despite its compact size, the circuit breaker offers the following benefits:
• Very high short-circuit breaking capacity
• Electronic trip units, versions with and without integrated metering function and optional communication interface
Electronic Trip Units (ETUs)
The current sensors of the 3VA6 comprise iron-cored transformers for the internal power supply and Rogowski coils for precise current measurement. Each transformer can be optimized accordingly for its specific task. Thanks to the high accuracy of current measurement, the 3VA6 molded case circuit breaker is suitable for power/energy measurement. In addition, finer adjustment of ground fault current monitoring is possible.
The Electronic Trip Units (ETUs) provide the following protection functions:
• Overload protection L ("L" = Long-time delay)
• Short-time delayed short-circuit protection S ("S" = Short-time delay) for time-selective response in case of a short-circuit
• Instantaneous short-circuit protection I ("I" = Instantaneous)
• Protection of the neutral conductor N against overload and short-circuit ("N" = Neutral)
• Protection against residual currents to ground ("G" = Ground fault)
• Ground fault detection (G alarm = ground fault alarm) does not trip the circuit breaker, but an indication is shown on the display and/or is communicated to higher-level systems via the communication path or EFB/MMB.
Energy management and communication The Electronic Trip Units (ETUs) provide the following energy management and communication functions:
• Metering function for current, voltage, power rating and energy
• Transfer of measured value data and breaker status information
• Remote parameter assignment of tripping thresholds and miscellaneous parameters
• Flexible use of digital inputs and outputs of the optionally available EFB300 external function box
• Commissioning/setting the plant topology and also individual breaker parameters with the "powerconfig" software package
• Testing and archiving with the TD300 and TD500 test devices (with powerconfig)
ETU556 LSI(G) with display
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd,
adjustable instantaneous short-circuit protection Ii and adjustable ground-fault alarm Ig
3VA6140-6JT41-0AA0
3VA6140-7JT41-0AA0
3VA6140-8JT41-0AA0
3VA6110-6JT41-0AA0
3VA6110-7JT41-0AA0
3VA6110-8JT41-0AA0
3VA6115-6JT41-0AA0
3VA6115-7JT41-0AA0
3VA6115-8JT41-0AA0
3VA6210-6JT41-0AA0
3VA6210-7JT41-0AA0
3VA6210-8JT41-0AA0
3VA6225-6JT41-0AA0
3VA6225-7JT41-0AA0
3VA6225-8JT41-0AA0
3VA6325-6JT41-0AA0
3VA6325-7JT41-0AA0
3VA6325-8JT41-0AA0
3VA6340-6JT41-0AA0
3VA6340-7JT41-0AA0
3VA6340-8JT41-0AA0
3VA6440-6JT41-0AA0
3VA6440-7JT41-0AA0
3VA6440-8JT41-0AA0
3VA6460-6JT41-0AA0
3VA6460-7JT41-0AA0
3VA6460-8JT41-0AA0
ETU560 LSIG with display
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
and adjustable ground-fault protection Ig
3VA6140-6JQ41-0AA0
3VA6140-7JQ41-0AA0
3VA6140-8JQ41-0AA0
3VA6110-6JQ41-0AA0
3VA6110-7JQ41-0AA0
3VA6110-8JQ41-0AA0
3VA6115-6JQ41-0AA0
3VA6115-7JQ41-0AA0
3VA6115-8JQ41-0AA0
3VA6210-6JQ41-0AA0
3VA6210-7JQ41-0AA0
3VA6210-8JQ41-0AA0
3VA6225-6JQ41-0AA0
3VA6225-7JQ41-0AA0
3VA6225-8JQ41-0AA0
3VA6325-6JQ41-0AA0
3VA6325-7JQ41-0AA0
3VA6325-8JQ41-0AA0
3VA6340-6JQ41-0AA0
3VA6340-7JQ41-0AA0
3VA6340-8JQ41-0AA0
3VA6440-6JQ41-0AA0
3VA6440-7JQ41-0AA0
3VA6440-8JQ41-0AA0
3VA6460-6JQ41-0AA0
3VA6460-7JQ41-0AA0
3VA6460-8JQ41-0AA0
4-pole, fixed-mounted, 3VA61 to 3VA64, up to 600 A
Electronic Trip Unit
ETU820 LI with display and metering function
With adjustable overload protection Ir and adjustable instantaneous short-circuit protection Ii
3VA6140-5KL41-0AA0
3VA6110-5KL41-0AA0
3VA6115-5KL41-0AA0
3VA6210-5KL41-0AA0
3VA6225-5KL41-0AA0
3VA6325-5KL41-0AA0
3VA6340-5KL41-0AA0
3VA6440-5KL41-0AA0
3VA6460-5KL41-0AA0
ETU830 LIG with display and metering function
With adjustable overload protection Ir, adjustable instantaneous short-circuit protection Ii
and adjustable ground-fault protection Ig
3VA6140-5KM41-0AA0
3VA6110-5KM41-0AA0
3VA6115-5KM41-0AA0
3VA6210-5KM41-0AA0
3VA6225-5KM41-0AA0
3VA6325-5KM41-0AA0
3VA6340-5KM41-0AA0
3VA6440-5KM41-0AA0
3VA6460-5KM41-0AA0
ETU820 LI with display and metering function
With adjustable overload protection Ir and adjustable instantaneous short-circuit protection Ii
3VA6140-6KL41-0AA0
3VA6140-7KL41-0AA0
3VA6140-8KL41-0AA0
3VA6110-6KL41-0AA0
3VA6110-7KL41-0AA0
3VA6110-8KL41-0AA0
3VA6115-6KL41-0AA0
3VA6115-7KL41-0AA0
3VA6115-8KL41-0AA0
3VA6210-6KL41-0AA0
3VA6210-7KL41-0AA0
3VA6210-8KL41-0AA0
3VA6225-6KL41-0AA0
3VA6225-7KL41-0AA0
3VA6225-8KL41-0AA0
3VA6325-6KL41-0AA0
3VA6325-7KL41-0AA0
3VA6325-8KL41-0AA0
3VA6340-6KL41-0AA0
3VA6340-7KL41-0AA0
3VA6340-8KL41-0AA0
3VA6440-6KL41-0AA0
3VA6440-7KL41-0AA0
3VA6440-8KL41-0AA0
3VA6460-6KL41-0AA0
3VA6460-7KL41-0AA0
3VA6460-8KL41-0AA0
ETU830 LIG with display and metering function
With adjustable overload protection Ir, adjustable instantaneous short-circuit protection Ii
and adjustable ground-fault protection Ig
3VA6140-6KM41-0AA0
3VA6140-7KM41-0AA0
3VA6140-8KM41-0AA0
3VA6110-6KM41-0AA0
3VA6110-7KM41-0AA0
3VA6110-8KM41-0AA0
3VA6115-6KM41-0AA0
3VA6115-7KM41-0AA0
3VA6115-8KM41-0AA0
3VA6210-6KM41-0AA0
3VA6210-7KM41-0AA0
3VA6210-8KM41-0AA0
3VA6225-6KM41-0AA0
3VA6225-7KM41-0AA0
3VA6225-8KM41-0AA0
3VA6325-6KM41-0AA0
3VA6325-7KM41-0AA0
3VA6325-8KM41-0AA0
3VA6340-6KM41-0AA0
3VA6340-7KM41-0AA0
3VA6340-8KM41-0AA0
3VA6440-6KM41-0AA0
3VA6440-7KM41-0AA0
3VA6440-8KM41-0AA0
3VA6460-6KM41-0AA0
3VA6460-7KM41-0AA0
3VA6460-8KM41-0AA0
4-pole, fixed-mounted, 3VA61 to 3VA64, up to 600 A
Electronic Trip Unit
ETU850 LSI with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-5KP41-0AA0
3VA6110-5KP41-0AA0
3VA6115-5KP41-0AA0
3VA6210-5KP41-0AA0
3VA6225-5KP41-0AA0
3VA6325-5KP41-0AA0
3VA6340-5KP41-0AA0
3VA6440-5KP41-0AA0
3VA6460-5KP41-0AA0
ETU856 LSI(G) with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd,
adjustable instantaneous short-circuit protection Ii and adjustable ground-fault alarm Ig,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-5KT41-0AA0
3VA6110-5KT41-0AA0
3VA6115-5KT41-0AA0
3VA6210-5KT41-0AA0
3VA6225-5KT41-0AA0
3VA6325-5KT41-0AA0
3VA6340-5KT41-0AA0
3VA6440-5KT41-0AA0
3VA6460-5KT41-0AA0
ETU860 LSIG with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
and adjustable ground-fault protection Ig
3VA6140-5KQ41-0AA0
3VA6110-5KQ41-0AA0
3VA6115-5KQ41-0AA0
3VA6210-5KQ41-0AA0
3VA6225-5KQ41-0AA0
3VA6325-5KQ41-0AA0
3VA6340-5KQ41-0AA0
3VA6440-5KQ41-0AA0
3VA6460-5KQ41-0AA0
ETU850 LSI with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd
and adjustable instantaneous short-circuit protection Ii,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-6KP41-0AA0
3VA6140-7KP41-0AA0
3VA6140-8KP41-0AA0
3VA6110-6KP41-0AA0
3VA6110-7KP41-0AA0
3VA6110-8KP41-0AA0
3VA6115-6KP41-0AA0
3VA6115-7KP41-0AA0
3VA6115-8KP41-0AA0
3VA6210-6KP41-0AA0
3VA6210-7KP41-0AA0
3VA6210-8KP41-0AA0
3VA6225-6KP41-0AA0
3VA6225-7KP41-0AA0
3VA6225-8KP41-0AA0
3VA6325-6KP41-0AA0
3VA6325-7KP41-0AA0
3VA6325-8KP41-0AA0
3VA6340-6KP41-0AA0
3VA6340-7KP41-0AA0
3VA6340-8KP41-0AA0
3VA6440-6KP41-0AA0
3VA6440-7KP41-0AA0
3VA6440-8KP41-0AA0
3VA6460-6KP41-0AA0
3VA6460-7KP41-0AA0
3VA6460-8KP41-0AA0
ETU856 LSI(G) with display and metering function
With adjustable overload protection Ir, adjustable delayed short-circuit protection Isd,
adjustable instantaneous short-circuit protection Ii and adjustable ground-fault alarm Ig,
with neutral protection against overload and short circuit from 20 %/40 % to 100 %/160 %
3VA6140-6KT41-0AA0
3VA6140-7KT41-0AA0
3VA6140-8KT41-0AA0
3VA6110-6KT41-0AA0
3VA6110-7KT41-0AA0
3VA6110-8KT41-0AA0
3VA6115-6KT41-0AA0
3VA6115-7KT41-0AA0
3VA6115-8KT41-0AA0
3VA6210-6KT41-0AA0
3VA6210-7KT41-0AA0
3VA6210-8KT41-0AA0
3VA6225-6KT41-0AA0
3VA6225-7KT41-0AA0
3VA6225-8KT41-0AA0
3VA6325-6KT41-0AA0
3VA6325-7KT41-0AA0
3VA6325-8KT41-0AA0
3VA6340-6KT41-0AA0
3VA6340-7KT41-0AA0
3VA6340-8KT41-0AA0
3VA6440-6KT41-0AA0
3VA6440-7KT41-0AA0
3VA6440-8KT41-0AA0
3VA6460-6KT41-0AA0
3VA6460-7KT41-0AA0
3VA6460-8KT41-0AA0