Danfoss 060G1105 pressure transmitter: verified MBS 3000 range, output and fitting details
Danfoss 060G1105 is an MBS 3000 pressure transmitter with a published 0–40 bar sealed-gauge range and 4–20 mA current output. Danfoss identifies an angular electrical connector and a G 1/4 pressure connection for this exact reference. The common product-family image is illustrative rather than an exact 060G1105 photograph.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete order number | 060G1105 |
| Manufacturer family | Danfoss MBS 3000 pressure transmitter |
| Pressure range | 0–40 bar, sealed gauge |
| Output signal | 4–20 mA current |
| Supply | 9–32 V DC in Danfoss product specifications |
| Pressure fitting | G 1/4, EN 837 |
| Electrical connector | Angular connector, Pg 9 / EN 175301-803-A |
| Enclosure | IP65 product specification; confirm cable and connector sealing |
The Danfoss 060G1105 details above describe the exact reference; final selection must also match the printed label and the installed equipment. The shared product image is only a category reference.
Measure the right pressure
Danfoss 060G1105 is a 0–40 bar sealed-gauge instrument. Do not assume that a 060G code with a close number has the same range or pressure reference. Compare the installed transmitter label, process pressure, overload conditions and instrument loop specification before approving 060G1105.
Loop and controller interface
The 4–20 mA output of 060G1105 must match the input card, loop supply and scaling in the receiving controller. Danfoss lists a 9–32 V DC supply interval for this product. Verify loop polarity, available voltage under load and alarm handling during commissioning.
Mechanical installation
Check the G 1/4 process port, sealing method, cable route and access for the angular connector. The connector and ingress protection should be assessed as an assembled system. Isolate and depressurize the line under the plant procedure before removing the old pressure transmitter.
Acceptance record
After fitting Danfoss 060G1105, check the zero and operating reading against a suitable reference. Record the transmitter range, controller scaling and any required calibration result. If a different 060G reference is offered, compare its range, output, process thread and connector one by one.
Similar-looking Danfoss order references
These 060G order numbers are close-looking catalogue references. Some denote other pressure ranges or even sensing accessories; none is presented as equivalent to 060G1105 without a separate manufacturer check.
Final order and receiving review
For Danfoss 060G1105, provide the full printed model, application duty, electrical or process interface, and current site documentation when requesting a quote. Do not approve a similar-looking number as a drop-in replacement without checking its own manufacturer data.
On receipt, inspect the Danfoss 060G1105 label and physical interfaces against the agreed order. Record condition, supplied accessories and the commissioning result so later maintenance enquiries can use the complete identity.