Technical profile and service boundary for ABB 1SDA073549R1, SACEE6.2H/MS
ABB 1SDA073549R1, SACEE6.2H/MS is treated here as the exact field reference within Emax 2 E6.2H/MS switch-disconnectors. This dossier is organized around interface evidence: what the installed item touches, which ratings must match, and how the result is accepted. The full designation matters; shared appearance is not proof of interchangeability.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | 1SDA073549R1, SACEE6.2H/MS |
| Product family | Emax 2 E6.2H/MS switch-disconnectors |
| Component role | E6.2H/MS 5000 A moving switch-disconnector |
| Exact ABB order reference | 1SDA073549R1 |
| ABB product series | Emax 2 E6.2H/MS switch-disconnectors |
| ABB series | Emax 2 E6.2H/MS |
| Rated current | 5000 A |
| Poles | 4 |
| Execution | Withdrawable moving part |
| Boundary | Switch-disconnector, not an overcurrent-trip breaker |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
For ABB 1SDA073549R1, SACEE6.2H/MS, read the values above together with the physical nameplate and the latest manufacturer instructions. A family description does not establish every optional feature of a particular shipped unit.
Incoming interface
Trace the incoming electrical, mechanical or signal interface to ABB 1SDA073549R1, SACEE6.2H/MS. Record supply characteristics, installation position, termination and any required upstream isolation.
A purchase for ABB 1SDA073549R1, SACEE6.2H/MS should state those incoming conditions explicitly; a matching body size does not prove the input interface is correct.
Application and functional boundary
ABB 1SDA073549R1, SACEE6.2H/MS is intended to switch a busbar or feeder within the engineered system. Identify the circuit, cabinet or process duty in the as-built drawing before selecting a replacement.
The functional boundary of ABB 1SDA073549R1, SACEE6.2H/MS includes connected devices and control logic. Note which neighboring components rely on its state, output or protective function.
Designation and option review
For ABB 1SDA073549R1, SACEE6.2H/MS, compare fixed part, frame, poles, terminals and mechanical interlocks. Review every suffix and mechanical option on both the old label and proposed replacement.
If a supplier proposes a variation of ABB 1SDA073549R1, SACEE6.2H/MS, request a written difference list covering electrical ratings, physical fit, approvals and service impact.
Outgoing interface
Follow the path leaving ABB 1SDA073549R1, SACEE6.2H/MS to the load, controller or next panel device. Compare terminal assignment, conductor preparation, feedback and accessible clearances.
Changes downstream of ABB 1SDA073549R1, SACEE6.2H/MS can invalidate an otherwise plausible substitution. Resolve the complete connected function with the responsible engineer.
Receiving and installation
Receive ABB 1SDA073549R1, SACEE6.2H/MS against the complete order string and inspect its markings, terminals, accessories and packaging. Keep revision information with the asset record.
Install ABB 1SDA073549R1, SACEE6.2H/MS only under the site's permit and isolation procedures. Use the manufacturer mounting and wiring instructions for the actual configuration.
Engineering hold points
Place ABB 1SDA073549R1, SACEE6.2H/MS on hold if its label, order confirmation or dimensions disagree with the approved drawing. Capture photographs and the exact discrepancy before releasing stock.
An ABB 1SDA073549R1, SACEE6.2H/MS hold is particularly important where a changed release, connector, enclosure or calibration would affect a safety or process function.
Commissioning evidence
After installing ABB 1SDA073549R1, SACEE6.2H/MS, verify drawout operation and isolation. Include the connected system in the acceptance test rather than checking only the loose component.
Record the ABB 1SDA073549R1, SACEE6.2H/MS as-left settings, measurements, test method and reviewer. Do not release equipment when unresolved alarms or interface mismatches remain.
Future spares decision
Archive the ABB 1SDA073549R1, SACEE6.2H/MS approval, supplier documentation and installation drawing together. That record allows a later buyer to distinguish an approved supersession from a merely similar code.
When the next ABB 1SDA073549R1, SACEE6.2H/MS spare is requested, recheck duty, firmware or approval changes against the current equipment rather than relying on a historic price line.
Decision record
Release ABB 1SDA073549R1, SACEE6.2H/MS only when the full designation, site fit and acceptance result agree.
Keep the ABB 1SDA073549R1, SACEE6.2H/MS manufacturer reference, inspection and commissioning evidence with the equipment file.