ABB 2CSB204101R3630 technical selection record

ABB 2CSB204101R3630 is the representative reference for the DDA200 residual-current block series. Its decision starts with the intended duty: add residual-current protection to a compatible breaker. The technical values below identify this representative, not every series variant.

Technical reference for the representative

Technical itemVerified value / selection note
Complete designation2CSB204101R3630
Product familyDDA200 residual-current block
Component roleDDA200 RCD add-on block
Exact ABB order reference2CSB204101R3630
ABB product seriesDDA200 residual-current block
Representative typeDDA204 A-63/0.3
FunctionResidual-current protection block
Related distinctionPoles and sensitivity vary
Final configurationConfirm exact nameplate, hardware revision and order options before purchase

Use the delivered ABB 2CSB204101R3630 marking and current manufacturer documentation to confirm all limits and options before engineering approval.

Decision 2 — compare electrical and mechanical interfaces

Before specifying ABB 2CSB204101R3630, verify frame pairing, poles, rated current and sensitivity. Compare drawings and the real installation, including terminals, clearances, mounting and the relevant supply.

The ABB DDA200 residual-current block family contains order references with possible differences. For ABB 2CSB204101R3630, a matching series name is insufficient without a full rating and connection check.

Decision 1 — identify the actual function

For ABB 2CSB204101R3630, document the existing device's job, connected circuit and expected behavior. The DDA200 RCD add-on block description helps browsing, but does not prove interchangeability.

Check whether ABB 2CSB204101R3630 is a direct maintenance replacement or part of a revised design. Treat any changed function as an engineering decision.

Decision 4 — receive and inspect

When ABB 2CSB204101R3630 arrives, compare the nameplate and order code with the purchase record. Check housing, connectors and supplied accessories for damage or omissions.

Place ABB 2CSB204101R3630 on hold if the delivered marking differs from the accepted specification. Resolve the difference before installation.

Decision 3 — document procurement boundaries

Quote ABB 2CSB204101R3630 with its complete designation and the approved series, function and application. Ask suppliers to identify every proposed change to current rating, options, firmware or accessories.

Keep ABB 2CSB204101R3630 separate from apparently similar products in another ABB series. Cross-series pairing requires explicit manufacturer compatibility evidence.

Decision 6 — plan a future replacement

A later replacement of ABB 2CSB204101R3630 must be checked again for series, interfaces, ratings and approvals. The related references below are useful for enquiry, not automatic substitutes.

If ABB 2CSB204101R3630 is unavailable, request a written comparison and repeat acceptance testing for any proposed alternate code.

Decision 5 — commission and retain evidence

Install ABB 2CSB204101R3630 only under the approved isolation and commissioning procedure, then test RCD operation after assembly. Record observed results against the design intent.

Store the ABB 2CSB204101R3630 test record with the asset tag, drawing revision and order history so a later technician can verify the exact configuration.

Release criterion

Approve ABB 2CSB204101R3630 after the identity, duty, interface and site test all agree with the approved specification.

Keep ABB 2CSB204101R3630 and its exact order reference on the final equipment record; series grouping is for navigation and selection review.

 

 

Pre:ABB 2CSA255103R1104 DS-ARC1: Technical Match and Installation Decision Guide Next:ABB TK201 1TNA920005R2102 | Procurement Questions and Site Verification