MO132-1.6 1SAM360000R1006: what the order code must match
MO132-1.6 1SAM360000R1006 is a magnetic-only manual motor starter for a defined industrial installation. When requesting MO132-1.6 1SAM360000R1006, keep its complete printed designation, hardware revision and project context together so that purchasing and engineering review the same component.
Technical identification and selection data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | MO132-1.6 1SAM360000R1006 |
| Product family | MO132 |
| Component role | magnetic-only manual motor starter |
| Type current | 1.6 A designation; verify feeder coordination |
| Overload | Magnetic-only unit: coordinate separate thermal protection |
| Order code | 1SAM360000R1006 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The MO132-1.6 1SAM360000R1006 data above identifies the published function and key selection checks. A rating or connection shared with another device does not establish an approved replacement for MO132-1.6 1SAM360000R1006.
Installation and return-to-service proof
For MO132-1.6 1SAM360000R1006, the controlled acceptance method is: Check switch action, trip indication and the complete protective chain rather than assuming thermal overload protection is built in. Record the actual results, not merely a pass/fail impression.
Before returning the equipment containing MO132-1.6 1SAM360000R1006 to production, verify isolation, protective coordination, terminal identification and any interlock or safety-related response.
Where this item works
For MO132-1.6 1SAM360000R1006, the intended duty is: Provide manual motor-circuit switching with magnetic short-circuit protection as specified by the feeder design. Capture the actual connected load or signal, site environment and operating sequence before purchase.
The installation record for MO132-1.6 1SAM360000R1006 should include a nameplate photograph, panel drawing and the failed unit's setting or software version when applicable.
Match the interface before ordering
The critical cross-check for MO132-1.6 1SAM360000R1006 is: Confirm the motor current, separate overload relay, prospective fault current and contactor coordination. A similar product outline, series name or current class alone is not enough.
Ask the supplier to identify any deviations from MO132-1.6 1SAM360000R1006 in connection hardware, function, approvals and accessories. Resolve them against the engineering drawing before accepting a substitute.
Same-series ordering references
These codes share the MO132 grouping with MO132-1.6 1SAM360000R1006, but option strings can alter ratings, wiring, firmware or certifications. They are not automatically interchangeable with MO132-1.6 1SAM360000R1006.
- 1SAM360000R1007 MO132-2.5
- MO132-4.0 1SAM360000R1008
- MO132-6.3 1SAM360000R1009
Buyer handover record
Quote MO132-1.6 1SAM360000R1006 in full, state quantity and destination, and attach the relevant panel photograph and drawing. Confirm whether accessories are included in the offered supply.
At receipt, compare the supplied label with MO132-1.6 1SAM360000R1006 and document any difference before installation. Retain the final part identity and the MO132-1.6 1SAM360000R1006 acceptance test with the asset history.