Identify OS160GD02P before replacement
OS160GD02P is a two-pole fuse switch-disconnector for a defined industrial installation. When requesting OS160GD02P, keep its complete printed designation, hardware revision and project context together so that purchasing and engineering review the same component.
Technical identification and selection data
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | OS160GD02P |
| Product family | OS160GD02P |
| Component role | two-pole fuse switch-disconnector |
| Rated current | 160 A |
| Poles | 2 |
| Fuse size | DIN 000/00 type family; confirm fuse selection |
| Order code | 1SCA116717R1001 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The OS160GD02P data above identifies the published function and key selection checks. A rating or connection shared with another device does not establish an approved replacement for OS160GD02P.
Match the interface before ordering
The critical cross-check for OS160GD02P is: Check fuse class and size, handle, shaft, enclosure, cable terminals and protection coordination. A similar product outline, series name or current class alone is not enough.
Ask the supplier to identify any deviations from OS160GD02P in connection hardware, function, approvals and accessories. Resolve them against the engineering drawing before accepting a substitute.
Installation and return-to-service proof
For OS160GD02P, the controlled acceptance method is: Confirm operating positions, fuse fit, interlock and isolation before the circuit is returned to service. Record the actual results, not merely a pass/fail impression.
Before returning the equipment containing OS160GD02P to production, verify isolation, protective coordination, terminal identification and any interlock or safety-related response.
Where this item works
For OS160GD02P, the intended duty is: Combine manual isolation and fuse-carrier function in an appropriately rated assembly. Capture the actual connected load or signal, site environment and operating sequence before purchase.
The installation record for OS160GD02P should include a nameplate photograph, panel drawing and the failed unit's setting or software version when applicable.
Same-series ordering references
These codes share the OS160GD02P grouping with OS160GD02P, but option strings can alter ratings, wiring, firmware or certifications. They are not automatically interchangeable with OS160GD02P.
No additional unassigned OS160GD02P code is recorded here for OS160GD02P.
Buyer handover record
Quote OS160GD02P in full, state quantity and destination, and attach the relevant panel photograph and drawing. Confirm whether accessories are included in the offered supply.
At receipt, compare the supplied label with OS160GD02P and document any difference before installation. Retain the final part identity and the OS160GD02P acceptance test with the asset history.