Technical service profile for ABB S201-C6
ABB S201-C6 should be specified as a complete device, not inferred from a similar family name. Its protection, control or measurement role must match the actual equipment and installation.
Technical data for model selection
| Technical item | Verified value / selection note |
|---|---|
| Complete designation | S201-C6 |
| Product family | S201 |
| Component role | single-pole S200 miniature circuit breaker |
| Poles | 1 |
| Rated current | 6 A |
| Trip curve | C |
| Icn | 6 kA under IEC/EN 60898-1 |
| Order code | 2CDS251001R0064 |
| Final configuration | Confirm exact nameplate, hardware revision and order options before purchase |
The stated S201-C6 data identify the selected reference and its engineering boundaries. Confirm the unit label, applicable standard and exact options before ordering or energizing.
Design intent
The intended duty of S201-C6 is to protect a single-pole branch circuit from overload and short circuit. Mark the circuit, asset or process tag and preserve the plant drawing that governs this function.
Do not assume a different suffix within S201 provides the same duty as S201-C6; ratings and accessory arrangements can differ.
What must match
Check S201-C6 against prospective fault level, 6 A load, curve C, busbar and terminal details. In procurement, ask for photographs or ABB documentation that show the complete designation and terminal configuration.
If the candidate S201-C6 differs from the installed device, document the difference and obtain an engineering decision before fitment.
Fault-finding baseline
For a future fault involving S201-C6, keep records of upstream supply, load, trip or output state and connected accessories. This separates a device issue from a wiring or process issue.
A replacement S201-C6 should be checked at the same duty point as the prior installation, with abnormal behavior investigated before return to service.
Installation controls
Before working on S201-C6, apply the approved isolation and permit controls. Capture the existing connections, settings and safety functions as a recoverable baseline.
Install S201-C6 with the correct conductor, panel spacing and environmental protection. Follow the ABB instructions for the specific construction rather than using a generic wiring assumption.
Handover evidence
For S201-C6, confirm circuit identification, insulation and protective-device operation. Record the measured result, witness and date beside the equipment tag.
Retain the final S201-C6 designation, revision, settings and test outcome in the maintenance record so later work does not rely on memory.
Related model references
The following S201 codes are indexed with ABB S201-C6 for search and enquiry. They remain configuration-specific; this grouping does not assert electrical, mechanical or approval interchangeability.
- 2CDS251001R0064 (S201-C6)
- 2CDS251103R0065, S201-B6NA
- S201- C 16A
- S201- C 20A
- S201- C 25A
- S201- C 32A
- S201- C 40A
- S201- C 50A
- S201- C 63A
- S201- C 6A
- S201-B32
- S201-C1
- S201-C2
- S201-C2 2CDS251001R0024
- S201-C3
- S201-C4
- S201-C6 (pn 2CDS251001R0064)
- S201-D16
- S201-D25
- S201-K16NA
- S201-K6
- S201-Z1 2CDS251001R0218
- S201-Z1.6 2CDS251001R0258
- S201-Z10 2CDS251001R0428
- S201-Z16 2CDS251001R0468
- S201-Z2 2CDS251001R0278
- S201-Z3 2CDS251001R0318
- S201-Z6 2CDS251001R0378
- S201-Z8 2CDS251001R0408
Enquiry checklist
Send the exact ABB S201-C6 designation with circuit or plant tag, required rating, accessories and approval. Confirm current lifecycle and delivery scope.
On receipt of S201-C6, compare label, package contents and documentation to the approved request. Hold any discrepancy for review before fitting.