Thermal Overload Relay ABB 1SAZ721201R1028 TF42-1.7 | 1.30–1.70 A Setting Range

description:Technical identification and selection guidance for ABB 1SAZ721201R1028 TF42-1.7, including verified family data, system compatibility and configuration checks....
BASIC INFO

1SAZ721201R1028 TF42-1.7: motor full-load setting and contactor pairing

ABB's thermal-overload catalog lists the TF42-1.7 under order code 1SAZ721201R1028 with a 1.30–1.70 A setting range and Class 10 trip behavior. The adjustment must be based on the actual motor nameplate and duty.

Verified identification and technical data

Technical itemVerified value / selection note
ABB order code1SAZ721201R1028
TypeTF42-1.7
Adjustable current1.30–1.70 A
Trip classClass 10 in ABB catalog
Protective roleMotor overload, not short-circuit interruption
CoordinationCheck upstream short-circuit protective device

For 1SAZ721201R1028 TF42-1.7, the table is an identification and selection aid. A nameplate, ABB order record and the actual installation still govern the final configuration.

1SAZ721201R1028 TF42-1.7 — decision note
Confirm the full type, revision and installation limits before treating any related code as a replacement.

Application decision

Review the duty before choosing 1SAZ721201R1028 TF42-1.7. Use the relay with a properly coordinated contactor and upstream short-circuit device. Check the motor's starting time, ambient conditions and whether reset should be manual or automatic under the machine's safety concept.

The decision for 1SAZ721201R1028 TF42-1.7 should record actual load or process limits, operating environment, normal behavior and the response to a fault. This avoids a selection based only on a familiar series name.

Same-series designation index

The codes below share a product family or an identified order-code relationship with 1SAZ721201R1028 TF42-1.7. They may differ in rating, software, connections, options or approvals; none is automatically interchangeable.

  • 1SAZ721201R1031 TF42-2.3
  • 1SAZ721201R1043 TF42-10
  • 1SAZ721201R1047 4013614398148 TF42-16
  • TF42-1.3
  • TF42-1.7
  • TF42-10
  • TF42-13
  • TF42-16
  • TF42-2.3
  • TF42-24 (20–24A)
  • TF42-35
  • TF42-38
  • TF42-4.2 (3.1–4.2A)
  • TF42-7.6
  • TF42-7.6 1SAZ721201R1040

Installation and proving

For 1SAZ721201R1028 TF42-1.7, With power isolated, record and set the approved motor-current value. Test trip contacts and reset behavior, then verify the motor starts without nuisance trips under its normal process load.

Record the as-left settings, test results and installed interfaces of 1SAZ721201R1028 TF42-1.7. Make the asset record searchable by the complete designation, not only by a short family label.

Order and compatibility gate

When specifying 1SAZ721201R1028 TF42-1.7, Confirm the matching contactor frame, mounting arrangement, auxiliary contacts and circuit diagram. A higher TF42 current range is not an acceptable substitute merely because it clips onto the same contactor.

Send the full designation 1SAZ721201R1028 TF42-1.7, hardware or serial revision, quantity, delivery need and nameplate photograph with the RFQ. Require written confirmation of any proposed successor or option-code change.

Handover record

The buyer and site engineer should agree on a single verified configuration for 1SAZ721201R1028 TF42-1.7, including accessories, documentation and the accepted test procedure. Keep deviations visible to both procurement and maintenance.

Retain 1SAZ721201R1028 TF42-1.7 in the purchase order, asset register and commissioning record. ABB family specifications help identify the device, but the approved project documents determine whether it is suitable for this installation.

 

 