KFD2-ELD-Ex16
Ground Fault Detection
16-channel isolated barrier, 24 V DC supply (Power Rail), Analog or digtial field device inputs, Monitors leakage current, Fault relay contact output, LED status indication, Test circuit for validation, Parallel connection for easy integration, Conformal coating, Rated voltage: 20 ... 30 V DC
KFD2-ER-Ex1.W.LB
Conductivity Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 kΩ ... 150 kΩ, Relay contact output, Fault relay contact output, Adjustable time delay up to 10 s, Minimum/maximum control, Line fault detection (LFD), Input: Conductive, Rated voltage: 20 ... 30 V DC, Output: relay
KFD2-SH-Ex1
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 ... 35 V DC, Output: relay, SIL/IEC 61508
KFD2-SH-Ex1.T.OP
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay output, Fault indication output, Line fault detection (LFD), Up to SIL3 acc. to IEC 61508, Up to PL d acc. to EN/ISO 13849, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: Transistor, SIL/IEC 61508
KFD2-SOT3-Ex1.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Passive transistor output, non-polarized, Passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
KFD2-SOT3-Ex1.LB.IO
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Isolated passive transistor output, non-polarized, Isolated passive fault output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 6150
KFD2-SOT3-Ex2
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
KFD2-SOT3-Ex2.IO
Switch Amplifier
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508, Input: NAMUR sensor, Rated voltage: 19 ... 30 V DC, Output: Transistor, SIL/IEC 61508
KFD2-SR2-Ex1.W
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508
KFD2-SR2-Ex1.W.LB
Switch Amplifier
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), Relay contact output, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508/IEC 61511, Input: NAMUR sensor, Rated voltage: 20 ... 30 V DC, Output: relay, SIL/IEC 61508