From nameplate to commissioning: HCD2-FBPS-1.500
Pepperl+Fuchs HCD2-FBPS-1.500 is a FieldConnex power-hub supply module used to feed a fieldbus segment through a compatible motherboard. This entry identifies the complete HCD2-FBPS-1.500 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of HCD2-FBPS-1.500. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Exact model | HCD2-FBPS-1.500 |
| Product role | FieldConnex power-hub supply module |
| Supply input | 19.2 to 35 V DC |
| Segment output | 28 to 29.5 V nominal |
| Current class | 500 mA |
| Mounting | Motherboard based |
| Variant check | Confirm the complete designation and current manufacturer documentation before replacement. |
Installation record
For a replacement HCD2-FBPS-1.500, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for HCD2-FBPS-1.500; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.
Process role
The job of HCD2-FBPS-1.500 is to feed a fieldbus segment through a compatible motherboard. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like HCD2-FBPS-1.500 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.
Test record
At commissioning, Calculate segment load and verify the correct Power Hub backplane. Test HCD2-FBPS-1.500 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that HCD2-FBPS-1.500 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.
Order record
An RFQ for HCD2-FBPS-1.500 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named HCD2-FBPS-1.500 variant where verified. Each other complete code needs its own specification review.
Related-looking model strings
These designations visually resemble HCD2-FBPS-1.500; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.
No additional same-pattern code is grouped with HCD2-FBPS-1.500 here; any alternative requires its own review.
Close-out
After the handover of HCD2-FBPS-1.500, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for HCD2-FBPS-1.500. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.