Pepperl+Fuchs ICDM-RX/TCP-4DB9/2RJ45-DIN: selection memo for maintenance and purchasing

Pepperl+Fuchs ICDM-RX/TCP-4DB9/2RJ45-DIN is a serial-to-Ethernet communication gateway used to bring multiple serial devices onto an Ethernet network. This entry identifies the complete ICDM-RX/TCP-4DB9/2RJ45-DIN designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of ICDM-RX/TCP-4DB9/2RJ45-DIN. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.

Key technical data

Technical itemVerified value / selection note
Exact modelICDM-RX/TCP-4DB9/2RJ45-DIN
Product roleserial-to-Ethernet communication gateway
Serial connectors4 DB9 ports in designation
Ethernet2 RJ45, 10/100 ports
Supply5 to 30 V DC per installation manual
MountingDIN-rail adapter
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Decision memo

The job of ICDM-RX/TCP-4DB9/2RJ45-DIN is to bring multiple serial devices onto an Ethernet network. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like ICDM-RX/TCP-4DB9/2RJ45-DIN may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.

Match the installed assembly

For a replacement ICDM-RX/TCP-4DB9/2RJ45-DIN, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for ICDM-RX/TCP-4DB9/2RJ45-DIN; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.

Prove the function

At commissioning, Record IP setup, serial mode and redundant supply before changeover. Test ICDM-RX/TCP-4DB9/2RJ45-DIN in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that ICDM-RX/TCP-4DB9/2RJ45-DIN has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.

Send a complete enquiry

An RFQ for ICDM-RX/TCP-4DB9/2RJ45-DIN should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named ICDM-RX/TCP-4DB9/2RJ45-DIN variant where verified. Each other complete code needs its own specification review.

Related-looking model strings

These designations visually resemble ICDM-RX/TCP-4DB9/2RJ45-DIN; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.

No additional same-pattern code is grouped with ICDM-RX/TCP-4DB9/2RJ45-DIN here; any alternative requires its own review.

Close-out

After the handover of ICDM-RX/TCP-4DB9/2RJ45-DIN, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for ICDM-RX/TCP-4DB9/2RJ45-DIN. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.

 

 