Pepperl+Fuchs INX360D-F99-I2E2-5M: what the exact variant must match

Pepperl+Fuchs INX360D-F99-I2E2-5M is a single-axis inclination sensor used for monitoring the absolute inclination of a moving structure. This product page centers on the precise INX360D-F99-I2E2-5M designation and practical fit decisions. Its shared montage is an illustrative category image, not a photograph of the exact variant. Confirm every site-specific electrical, mechanical and approval requirement against the current manufacturer's documentation before a purchase or changeover.

Technical data for the exact designation

Technical itemVerified value / selection note
Exact modelINX360D-F99-I2E2-5M
Product rolesingle-axis inclination sensor
Angular range0 to 360 degrees
Analog output4 to 20 mA
Switch outputs2 PNP normally-open outputs
Connection5 m PUR cable
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Service brief

Use INX360D-F99-I2E2-5M for monitoring the absolute inclination of a moving structure. A service technician should identify the upstream and downstream interfaces before disturbing the connection.

Before the change

For INX360D-F99-I2E2-5M, confirm sensor orientation, output scaling, taught switch points and cable route. Record the installed nameplate, matching device, space envelope and existing configuration. An appearance match is only a starting point: signal direction, power, interface and certification must be considered separately.

After the change

With INX360D-F99-I2E2-5M installed, compare display/current with two physical angle references. Compare observed values with a known test condition and record the controller or diagnostic response. Repeat at the relevant operating limits so that an intermittent wiring or setup problem does not go unnoticed.

Supply-chain check

For a INX360D-F99-I2E2-5M enquiry, keep the I2E2-5M output and cable option in the order. Provide the full label, circuit or mounting drawing and operating conditions. Ask for written confirmation before accepting any substituted suffix, especially when a related-looking code has different terminals, approval or function.

Related-looking designations

These names visually resemble INX360D-F99-I2E2-5M and are grouped as identification references. They may differ in function, circuit values, mounting, communications and hazardous-area approval. Do not apply the technical values of INX360D-F99-I2E2-5M to another complete designation without its own specification.

  • INX360D-F99-I2E2-V15

Final record

Keep the completed check with the maintenance history for INX360D-F99-I2E2-5M. If site conditions change, review the current datasheet and repeat the relevant electrical, mechanical and functional checks. The values in this page identify INX360D-F99-I2E2-5M where stated; they do not define every visually related code.

 

 