Pepperl+Fuchs IQT1-F61-IO-V1: selection memo for maintenance and purchasing
Pepperl+Fuchs IQT1-F61-IO-V1 is a HF RFID read-write station used to exchange tag data over IO-Link. This entry identifies the complete IQT1-F61-IO-V1 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of IQT1-F61-IO-V1. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.
Key technical data
| Technical item | Verified value / selection note |
|---|---|
| Exact model | IQT1-F61-IO-V1 |
| Product role | HF RFID read-write station |
| Interface | IO-Link 1.1 |
| Data rate | COM3, 230.4 kbit/s |
| RFID | ISO/IEC 15693 family |
| Connection | M12 V1 |
| Variant check | Confirm the complete designation and current manufacturer documentation before replacement. |
System boundary
The job of IQT1-F61-IO-V1 is to exchange tag data over IO-Link. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like IQT1-F61-IO-V1 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.
Replacement gate
For a replacement IQT1-F61-IO-V1, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for IQT1-F61-IO-V1; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.
Record the complete IQT1-F61-IO-V1 code before comparing any similar-looking part.
Acceptance evidence
At commissioning, Check tag standard, IO-Link port parameters and read distance. Test IQT1-F61-IO-V1 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that IQT1-F61-IO-V1 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.
Purchasing handoff
An RFQ for IQT1-F61-IO-V1 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named IQT1-F61-IO-V1 variant where verified. Each other complete code needs its own specification review.
Related-looking model strings
These designations visually resemble IQT1-F61-IO-V1; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.
No additional same-pattern code is grouped with IQT1-F61-IO-V1 here; any alternative requires its own review.
Close-out
After the handover of IQT1-F61-IO-V1, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for IQT1-F61-IO-V1. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.