low voltage

Hotline

Pepperl+Fuchs OJ500-M1K-E23 Technical Product Record | Fiber-Optic Sensor Amplifier and System Checks

description:Pepperl+Fuchs OJ500-M1K-E23 fiber-optic sensor amplifier: technical data, system boundary, replacement and commissioning checks....
BASIC INFO

The exact OJ500-M1K-E23 designation in an industrial system

Pepperl+Fuchs OJ500-M1K-E23 is a fiber-optic sensor amplifier used to detect a target through a matched fiber-optic arrangement. This entry identifies the complete OJ500-M1K-E23 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of OJ500-M1K-E23. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.

Key technical data

Technical itemVerified value / selection note
Exact modelOJ500-M1K-E23
Product rolefiber-optic sensor amplifier
Optical systemGlass-fiber compatible sensor
Supply10 to 30 V DC
OutputPNP switching
Switching frequency200 Hz or 1.5 kHz selectable
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

Decision memo

The job of OJ500-M1K-E23 is to detect a target through a matched fiber-optic arrangement. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like OJ500-M1K-E23 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.

Match the installed assembly

For a replacement OJ500-M1K-E23, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for OJ500-M1K-E23; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.

Prove the function

At commissioning, Prove the fitted fiber, light/dark choice and real target contrast. Test OJ500-M1K-E23 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that OJ500-M1K-E23 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.

Send a complete enquiry

An RFQ for OJ500-M1K-E23 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named OJ500-M1K-E23 variant where verified. Each other complete code needs its own specification review.

Related-looking model strings

These designations visually resemble OJ500-M1K-E23; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.

No additional same-pattern code is grouped with OJ500-M1K-E23 here; any alternative requires its own review.

Close-out

After the handover of OJ500-M1K-E23, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for OJ500-M1K-E23. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.

 

 

Pre:Buying Pepperl+Fuchs MMB70-12GH50-1N Magnetic Field Sensor for an Existing Installation Next:Pepperl+Fuchs IQT1-F61-IO-V1 Hf Rfid Read-Write Station — Industrial Fit and Technical Selection