low voltage

Hotline

Pepperl+Fuchs ML300-T-6m-RT/98 Photoelectric Thru-Beam Emitter | 6 m ML300 Pairing and M8 Connection Guide

description:Pepperl+Fuchs ML300-T-6m-RT/98 photoelectric thru-beam emitter: technical ratings, selection limits, installation checks and related designations for exact-code procurement....
BASIC INFO

Selecting ML300-T-6m-RT/98 for a matched ML300 thru-beam photoelectric installation

Pepperl+Fuchs ML300-T-6m-RT/98 is the transmitting half of an ML300 thru-beam sensor system. It sends a visible red light beam toward a separately installed receiver. The quoted 6 m range belongs to the specified paired arrangement; ML300-T-6m-RT/98 by itself is not a complete switching sensor. The shared montage is illustrative and does not establish the exact emitter or receiver delivered.

Key technical data

Technical itemVerified value / selection note
Exact typeML300-T-6m-RT/98 emitter
Sensing systemML300 thru-beam photoelectric pair; emitter and receiver are separate components
System effective range0 to 6 m for the specified emitter/receiver pair
LightModulated visible red LED, approximately 660 nm
System supply10 to 30 V DC in the referenced paired-system data
ConnectionM8 x 1 connector; verify pin assignment on the exact unit
ProtectionIP65 for the referenced ML300 pair
Selection boundaryReceiver output and switching behavior depend on the paired receiver variant

Emitter and receiver pairing

The letters in ML300-T-6m-RT/98 matter: T denotes the emitter, whereas an ML300-R code denotes a receiver. Specify both halves where a complete light barrier is required. Receiver suffixes can change output polarity, light-on/dark-on behavior and connection. Compare the actual receiver label and wiring diagram before replacement.

Optical installation

Mount ML300-T-6m-RT/98 and its receiver on a stable axis with unobstructed line of sight. Verify usable separation, target size, ambient light, vibration and contamination at the optical faces. Check alignment and excess signal margin under normal machine motion rather than only during a static bench test.

Electrical and service checks

Confirm the 10 to 30 V DC supply and M8 connection from the exact product document before energizing ML300-T-6m-RT/98. Route sensor wiring away from high-noise motor cables as required by the installation design. If detection becomes intermittent, inspect alignment, dirt, connector sealing and receiver diagnostics before replacing the transmitter.

Buyer information

For a ML300-T-6m-RT/98 enquiry, provide the transmitter label, matching receiver code, cable/connector choice, mounting distance and desired switching behavior. Do not infer an NPN or PNP output from the emitter part number: the switching output resides in the receiver.

Related model references

The first code is a receiver, the second is a recorded form of this emitter, and the last is another ML300 configuration. Similar names do not mean the pieces are interchangeable.

  • ML300-R-6m-RT/25/98/103
  • ML300-T-6M-RT/98 238194
  • ML300-8-H-200-RT/25/98/103

Manufacturer documentation

For ML300-T-6m-RT/98, check the latest Pepperl+Fuchs datasheet and the complete label against the installed device before final selection or commissioning.

Additional visually similar Pepperl+Fuchs model designations

These complete codes are collected for model search and identification because their printed designations look similar. They may represent different products, electrical interfaces, mechanical sizes or approvals. They are not declared interchangeable with ML300-T-6m-RT/98. Verify each complete designation against the manufacturer record and the installed equipment before ordering.

  • ML100-55/102/115 (210544)
  • ML100-55/103/115
  • ML100-55/103/115a
  • ML100-55/103/115b
  • ML100-55/95/103
  • ML100-8-H-250-BU/102/115
  • ML100-8-H-250-RT/102/115
  • ML100-8-H-350-RT/95/103
  • ML100-8-HGU-100-RT/102/115/162
  • ML18-2397
  • ML18-2397 418676
  • ML4.2-8-H-20-RT/40b/95/110 183447
  • ML4.2-8-H-40-IR-2449
  • ML4.2-8-H-40-RT/40b/95/110 (183449)
  • ML4.2-8-H-60-RT/40B/95/110
  • ML4.2-8-H-60-RT/40b/95/110 (183451)
  • ML4.2-P-8M-RT/40b/76a/95/110
  • ML4.2-R/40B/95/110
  • ML7-54-G/25/136/115B
  • ML7-8-H-140-RT/59/65a/115/136
  • ML8-8-HGU-50-RT/103/143/162 (204318)
  • MLV41-54-G-1371 190524
  • MLV41-54-G-IO/25/92/136

 

 

Pre:Pepperl+Fuchs NCB5-18GM40-N0 NAMUR Inductive Proximity Sensor | M18 Flush Mount, 5 mm Sensing and Cable Selection Next:Pepperl+Fuchs UC2000-30GM-IUR2-V15 Ultrasonic Distance Sensor | 80–2000 mm Range, Analog Outputs and M30 Mounting