Confirming the installed interface for ASM58N-F2AK1A0GN-1213

Pepperl+Fuchs ASM58N-F2AK1A0GN-1213 is a absolute rotary encoder used to retain shaft position information across a power cycle. This entry identifies the complete ASM58N-F2AK1A0GN-1213 designation and shows the technical data that can be used as a starting point. The shared main image is a Pepperl+Fuchs category reference montage, not an exact photograph of ASM58N-F2AK1A0GN-1213. Final selection still requires the fitted label, the latest manufacturer record and the actual site drawing.

Key technical data

Technical itemVerified value / selection note
Exact modelASM58N-F2AK1A0GN-1213
Product roleabsolute rotary encoder
FamilyASM58N absolute encoder
Housing58 mm class
ResolutionVerify exact complete code and installed parameter set
ConnectionConfirm fitted cable or connector on the nameplate
Variant checkConfirm the complete designation and current manufacturer documentation before replacement.

System boundary

The job of ASM58N-F2AK1A0GN-1213 is to retain shaft position information across a power cycle. Define its boundary in the real installation: what connects upstream, what response is required downstream, how it is powered and how it is mounted. A model that looks like ASM58N-F2AK1A0GN-1213 may not provide the same circuitry or approvals. Capture the present configuration before removal, including any addresses, calibration, scaling, taught limits or software settings.

Replacement gate

For a replacement ASM58N-F2AK1A0GN-1213, compare the full printed code character by character. Confirm supply, I/O direction, signal type, terminal or plug pinout, operating environment and mechanical clearances. If the circuit has functional-safety or hazardous-area requirements, obtain the exact approval documents for ASM58N-F2AK1A0GN-1213; the visual similarity of another code is not a valid substitute. Include mating heads, reflectors, boards, cables and licences as separate line items where needed.

Record the complete ASM58N-F2AK1A0GN-1213 code before comparing any similar-looking part.

Acceptance evidence

At commissioning, Check mechanical coupling, interface protocol and the controller's absolute count. Test ASM58N-F2AK1A0GN-1213 in the assembled system using a known input or mechanical condition, then read the corresponding output and controller response. Repeat at the low and high ends of the real operating window. A status LED alone cannot prove that ASM58N-F2AK1A0GN-1213 has the correct settings, connected accessory or alarm action. Keep the measured values and any deviations in the maintenance record.

Purchasing handoff

An RFQ for ASM58N-F2AK1A0GN-1213 should quote the complete designation, required quantity, installed controller or host, connection style, certification need and the intended operating environment. Request confirmation for any alternate suffix. Related-looking models are indexed below to help identify inventory, but technical table values on this page apply only to the named ASM58N-F2AK1A0GN-1213 variant where verified. Each other complete code needs its own specification review.

Related-looking model strings

These designations visually resemble ASM58N-F2AK1A0GN-1213; they can still have different functions, ratings, interfaces and approvals. Verify each complete code independently before ordering or substitution.

  • AVM58N-011AAR0BN-1213
  • AVM58N-011AAR0GN-1212
  • AVM58N-011K1RHGN-1212
  • AVM58N-012AAR0GN-1213

Close-out

After the handover of ASM58N-F2AK1A0GN-1213, archive the exact label, configuration backup, drawings and test result. If the process or host changes later, redo the relevant match and acceptance checks for ASM58N-F2AK1A0GN-1213. Do not treat the product montage or the related-code index as a wiring diagram or a declaration of interchangeability.

 

 