Checking the exact PXV100S-F200-SSI-V19 configuration from cabinet to process
Pepperl+Fuchs PXV100S-F200-SSI-V19 is a optical positioning read head selected to read a coded position strip for absolute travel feedback. The full PXV100S-F200-SSI-V19 code is the identification anchor for this page. The shared main montage illustrates the Pepperl+Fuchs category and is not a photograph of this exact option. Before using PXV100S-F200-SSI-V19 as a spare, compare the installed label and project drawing with the current manufacturer documentation.
Technical specification and identity
| Technical item | Verified value / selection note |
|---|---|
| Exact model | PXV100S-F200-SSI-V19 |
| Product role | optical positioning read head |
| Positioning | Optical reading head |
| Primary interface | SSI |
| Supply | 15 to 30 V DC |
| Output code | Gray or binary, programmable |
| Variant check | Confirm the complete designation and current manufacturer documentation before replacement. |
Before the change
For installation of PXV100S-F200-SSI-V19, document the existing assembly before disturbing it. Photograph the full label, terminals, cable exits, brackets and adjacent modules; mark conductors and save any controller or software configuration. Compare voltage, polarity, loading and environmental limits against the exact PXV100S-F200-SSI-V19 technical record. If PXV100S-F200-SSI-V19 is part of a safety or hazardous-area circuit, the site-approved design and certificates take precedence over an appearance match.
Start with the real duty of PXV100S-F200-SSI-V19: read a coded position strip for absolute travel feedback. Then trace what connects to PXV100S-F200-SSI-V19, including its power source, input or target, outgoing signal and mechanical support. Check strip alignment, SSI word configuration and M12 connections. Record the actual site settings and the parts that are supplied separately. This matters because a near-identical type string can conceal a different output, connection, dimension or approval.
At commissioning
After fitting PXV100S-F200-SSI-V19, prove its function in the completed system, not merely its power-on indication. Apply a known field condition, read the downstream controller or diagnostic tool, and repeat at both normal and limiting conditions. For PXV100S-F200-SSI-V19, check strip alignment, ssi word configuration and m12 connections. Capture the observed readings, alarm states and any parameter changes so the maintenance record explains why PXV100S-F200-SSI-V19 was accepted.
At purchasing handoff
When asking for PXV100S-F200-SSI-V19, include the entire type code, quantity, installation location, applicable approval, mating connector or board and required accessories. Ask a supplier to confirm the exact PXV100S-F200-SSI-V19 designation in writing. A proposed equivalent must be checked independently for electrical behavior, mounting, software and certifications. The related codes below are search and identification references; they are not a declaration that they interchange with PXV100S-F200-SSI-V19.
Related-looking designations
The following strings resemble PXV100S-F200-SSI-V19 in the supplied product family. Their full suffixes may change function, ratings, mechanical fit or approval; consult each exact manufacturer's record before a substitute is used.
No additional same-pattern designation is grouped with PXV100S-F200-SSI-V19 here. An alternate part still needs a separate exact-code check.
Close-out note
For future service of PXV100S-F200-SSI-V19, retain the final wiring diagram, settings, test result and replacement reference together. Recheck the data for PXV100S-F200-SSI-V19 if the connected controller, process conditions or regulatory setting changes. The table describes the named PXV100S-F200-SSI-V19 where a value is stated; do not extend those values automatically to another listed code.